User manual YAMAHA DME64N-24N

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAMAHA DME64N-24N. We hope that this YAMAHA DME64N-24N user guide will be useful to you.


YAMAHA DME64N-24N : Download the complete user guide (2735 Ko)

You may also download the following manuals related to this product:

   YAMAHA DME64N-24N (9448 ko)
   YAMAHA DME64N-24N (4383 ko)
   YAMAHA DME64N-24N (4516 ko)
   YAMAHA DME64N-24N (3096 ko)
   YAMAHA DME64N-24N (3865 ko)
   YAMAHA DME64N-24N (4 ko)
   YAMAHA DME64N-24N (5 ko)
   YAMAHA DME64N-24N annexe 1 (4712 ko)
   YAMAHA DME64N-24N annexe 1 (3607 ko)
   YAMAHA DME64N-24N annexe 2 (4742 ko)
   YAMAHA DME64N-24N annexe 1 (3632 ko)
   YAMAHA DME64N-24N annexe 2 (4753 ko)
   YAMAHA DME64N-24N annexe 1 (3606 ko)
   YAMAHA DME64N-24N annexe 2 (4750 ko)
   YAMAHA DME64N-24N V1.2 SUPPLEMENTAL NOTES (197 ko)
   YAMAHA DME64N-24N V1.2 SUPPLEMENTAL NOTES (199 ko)
   YAMAHA DME64N-24N V1.2 SUPPLEMENTAL NOTES (199 ko)
   YAMAHA DME64N-24N annexe 1 (3351 ko)
   YAMAHA DME64N-24N annexe 2 (4403 ko)
   YAMAHA DME64N-24N V1.2 SUPPLEMENTAL NOTES (558 ko)

Manual abstract: user guide YAMAHA DME64N-24N

Detailed instructions for use are in the User's Guide.

[. . . ] DIGITAL MIXING ENGINE Owner's Manual EN Explanation of Graphical Symbols CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The above warning is located on the top of the unit. IMPORTANT SAFETY INSTRUCTIONS 1 2 3 4 5 6 7 8 Read these instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. [. . . ] SLOT-1, SLOT-2, SLOT-3, SLOT-4: A card installed in the corresponding I/O slot is currently selected for MIDI input. 2 NO T E Panel Operation and Displays 1 3 Edit using the "List Parameters" editing procedure described on page 41. NOTE When the DME64N/24N is functioning as the zone master and is connected to a computer running the DME Designer application via USB, the MIDI port being used by the DME Designer will not be available. This page will not appear on the ICP1 display. 1 Card Name The name of the installed card appears here. The input setting is on the left and the output setting is on the right. No Display (Default): 44. 1/48 kHz audio signal transfer. SP (Double Speed): An 88. 2/96 kHz capable card is installed, allowing direct transfer at 88. 2 or 96 kHz. CH (Double Channel): A 44. 1/48 kHz card is installed, and 88. 2 or 96 kHz audio is transferred by using two 44. 1/48 kHz channels to transfer each channel of 88. 2/96 kHz audio. The number of audio channels that can be handled in this mode is half the number of channels normally handled by the card. 2 DAW Specifies the type of MIDI device (DAW control surface, etc. ) to be connected. The choices are OFF, TYPE1, and TYPE2. OFF: Use this setting when any MIDI device other than a general-purpose ProTools controller (HUI protocol) or general-purpose Logic or Cubase controller (Mackie control protocol) is to be connected. TYPE1: Use this setting when a general-purpose ProTools controller (HUI protocol) is to be connected. TYPE2: Use this setting when a general-purpose Logic or Cubase controller (Mackie control protocol) is to be connected. Edit using the "List Parameters" editing procedure described on page 41. Refer to the DAW controller owner's manual as well as the DME Designer manual for setup details. 52 DME64N/24N Owner's Manual Utility Displays NO T E "DAW" stands for "Digital Audio Workstation. " ProTools, Logic, and Cubase are DAW applications, and this parameter provides direct compatibility with a number of physical controls surfaces that are available for use with these DAW software packages. GPI Setup (GPI) Page Input calibration parameters for the [GPI] connector. NOTE This page will not appear on the ICP1 display. The following parameters are available when the DAW parameter is set to OFF. 3 CH Specifies the device's MIDI transmit and receive channel: 1 ~ 16. Edit using the "List Parameters" editing procedure described on page 41. 4 Program Change Turns transmission and reception, the omni mode, and echo ON or OFF for MIDI program change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. 5 Control Change Turns transmission and reception, the omni mode, and echo ON or OFF for MIDI control change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. 6 Parameter Change Turns transmission and reception, and echo ON or OFF for MIDI parameter change messages. Move the cursor to the required parameter, then press the [ENTER] button to alternately turn ON and OFF. ] To reset the calibration, use the [E [ ] [ ] [F ] buttons to select ALL to reset all inputs, or select an individual input from 1 to 16 to be reset, then press the [ENTER] button. To set the MAX value, use the [E [ ] [ ] [F ] ] buttons to select ALL to set all inputs, or select an individual input from 1 to 16 to be set, then press the [ENTER] button to set the MAX value to the current input voltage. To set the MIN value, use the [E [ ] [ ] [F ] ] buttons to select ALL to set all inputs, or select an individual input from 1 to 16 to be set, then press the [ENTER] button to set the MIN value to the current input voltage. 4 Calibration Info Shows the calibration settings as well as the current input voltage. DME64N/24N Owner's Manual 53 Panel Operation and Displays Utility Displays Head Amplifier Setup (HA) Page Provides access to the head amplifier settings. Refer to "REMOTE Connection" on page 34 for head amplifier control signal connection. NO T E This page will not appear on the ICP1 display. 2 WCLK (AD8HR/AD824 only) Specifies the word clock signal to be used by the head amplifier(s). [. . . ] 19, 33 word clock master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Word Clock Setup (WCLK) Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 word clock slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 78 DME64N/24N Owner's Manual For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA DME64N-24N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA DME64N-24N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.