User manual WINDCHASER WDH-928

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WINDCHASER WDH-928. We hope that this WINDCHASER WDH-928 user guide will be useful to you.


WINDCHASER WDH-928 : Download the complete user guide (753 Ko)

Manual abstract: user guide WINDCHASER WDH-928

Detailed instructions for use are in the User's Guide.

[. . . ] After unpacking, place the unit upright to allow the cooling agent to stabilize, and wait 3 hours before use. Do not damage the power cord. Always keep unit in an upright position to avoid any damage to the cooling system. Be sure that the air inlets and outlets are not blocked or covered up. [. . . ] Upon reaching the desired humidity level, the dehumidifier will automatically stop. The dehumidifier will automatically turn back on once the humidity level exceeds the selected setting. Emptying the Water Tank When the water tank is full, the indicator light will illuminate and the dehumidifier will automatically shut off. Remove the water tank, empty water, place tank back in unit and unit will return to operation mode. Hold the water tank by the handle as shown. Hold the tank by the sides with both hands to empty the water. -2- Hooking up a Continuous Drain Hose: For continuous drainage via gravity, use a flexible PVC tube approx. 0. 5 inches (1. 3cm) in diameter, commonly found at home furnishing stores, cut to the required length. Lightly tap open the drain hole on the left of the housing. Insert the flexible PVC tube into the drain hole on the unit. When using the continuous drain feature, make sure the drain tube is laid flat horizontally and fastened in place; avoid overlapping or depressing, and make sure it lays lower than the drain hole. Safety precaution: Never handle any power cord with wet hands. Refrain from using multiple power outlets to avoid electrical sparks. Keep the unit and control panel free of contact with moisture. Never pull from the power cord to avoid electrical shorts. For optimal safety, remove the power cord and turn off the unit whenever cleaning or servicing is required. Refrain from disassembling or servicing the unit, unless by a trained service technician. -3- Warning: Never insert any foreign objects into the unit to avoid hazards. Keep all combustibles, such as gasoline, away from the unit. Keep the electrical plug clean at all times. Never drape clothing over the dehumidifier for drying. Never spray insecticide or apply grease paint near the unit to avoid damage to the plastic parts and to avoid fire hazards. Operating precaution: Refrain from leaving the door or windows open to maximize dehumidifying efficiency. Clean the filter regularly to ensure maximum air intake and dehumidifying efficiency. Keep the unit away from all heat sources to prevent the plastic parts from damage, which may lead to hazards. -4- Operating precaution: Refrain from operating the dehumidifier near the sink. Refrain from operating the dehumidifier in a confined closet. Allow adequate clearance around all sides of the dehumidifier. Maintenance tips: Always make sure the power plug has been removed prior to maintenance or repair. 1) Caring for housing: A. For dust buildup, a mild cleansing agent may be used to gently wipe clean the surface. 2) Cleaning the air filter: The air filter serves to filter out the dust or odor in the air. Under normal operating conditions, clean the filter on a biweekly basis by removing the filter and vacuuming the dust. Emergency Handling: In the event the dehumidifier should malfunction or emit strange odors, please remove the plug immediately, and contact WindChaser Customer Service (see Warranty); do not attempt to disassemble the unit to avoid electrical hazards. -5- Electrical specifications Model Current feed Dehumidifying Capacity WDH-928 115V, 60Hz 30 PINTS 80. 6 F 60%RH (27 C 60%RH) 570 watts Power rating Dimensions (WxHxD) 15. 35 in x 24. 09 in x 12. 36 in (39. 0 cm x 61. 2 cm x 31. 4 cm) 46. 29 lbs. (21 kgs) 41 F - 95 F (5 C - 35 C) Gross weight Applicable operating range If the power supply cord is damaged, please contact WindChaser Customer Service. PRODUCT LIMITED WARRANTY This warranty applies to new product only and excludes optional accessories and attachments. Extended compressor warranty applies only to product with manufacturing dates beginning January 1, 1998. During the first year from the date of original purchase, this product is warranted to be free from defects in materials or workmanship under normal use, service and maintenance. During the 2nd through 5th years from the date of original purchase, the compressor (part only) is warranted against defects in material or workmanship under normal use, service and maintenance. This warranty applies to the original purchaser subject to the following terms and conditions: WHAT IS COVERED: The product's components as originally installed by the manufacturer that are defective in materials or workmanship under normal use, service and maintenance. WHAT IS NOT COVERED BY THIS WARRANTY: This warranty does not extend to or cover: (1) Any defect due to the negligence of others; failure to install, operate or maintain unit or accessories and attachments in accordance with installation instructions (instruction manual is furnished with each new unit); unreasonable use; accidents; alteration, use of unauthorized or non-standardized parts, accessories and attachments; acts of God; theft; vandalism; blown fuses; electrical malfunction. (i. e. , as resulting from power surges, shorted or overloaded circuits outlets of wiring utility power quality, etc. ), incorrect installation; use of any power source other than that specified on the Product's specification label; or repair by anyone other than a service facility specified by an authorized WINDCHASER representative. (5) Normal wear and tear of parts including but not limited to, hoses, cables, accessories and attachments. (6) Shipping, handling, packaging and delivery costs of the product, parts or accessories. (8) Diagnosing, repairing, removing, installing, shipping, servicing and/ or handling costs of either defective parts or replacement parts as relating to Extended 4 Year Compressor Warranty. WHO IS COVERED The original purchaser from a retailer or licenced air conditioning contractor. [. . . ] WINDCHASER SHALL NOT BE LIABLE FOR THE LOSS OF USE OF THE PRODUCT, ITS COMPONENTS, ACCESSORIES AND ATTACHMENTS, INCONVENIENCE, LOSS OR ANY OTHER DAMAGES, DIRECT OR CONSEQUENTIALARISING OUT OF THE USE OF, OR INABILITY TO USE THE PRODUCT, ITS COMPONENTS AND ACCESSORIES OR DAMAGES RESULTING FROM OR ATTRIBUTABLE TO DEFECTS IN THE PRODUCT, ITS COMPONENTSANDACCESSORIES. NO ONE OTHER THAN WINDCHASER HAS AUTHORITY TO EXTEND OR MODIFY THE TERMS OF THIS LIMITED WARRANTY IN ANY MANNER WHATSOEVER. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so these limitations or exclusions may not apply to you. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WINDCHASER WDH-928




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WINDCHASER WDH-928 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.