User manual VISONIC KP-140 PG2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VISONIC KP-140 PG2. We hope that this VISONIC KP-140 PG2 user guide will be useful to you.


VISONIC KP-140 PG2 : Download the complete user guide (463 Ko)

Manual abstract: user guide VISONIC KP-140 PG2

Detailed instructions for use are in the User's Guide.

[. . . ] The main features of the KP-140 PG2 are: · Status, alarm memory, and trouble data retrieval from the control panel · Automatic reporting of low battery voltage. · Back tamper and battery compartment tamper · Automatic supervision messages to the control panel. · Exit/entry beeps · Long-life 4 year (with entry/exit beeps) / 5 year (without entry/exit beeps) battery life expectancy, 3 VDC lithium battery. Communication Indications User's Guide Description Red LED lights shortly, then red LED lights 1 sec. [. . . ] Four options are offered: Not used: No functions assigned to AUX button. Stop Beeps: Pressing the AUX button will cause the control panel and the KP-140 PG2 device to mute the beeps. Skip exit delay: Pressing the AUX button will immediately stop the exit delay. or Select between "ON", "OFF" and "OFF @ Home". Here you determine whether or not to activate the exit ­ entry beeps, or, activate the exit ­ entry beeps when armed AWAY only. Here you determine whether or not the control panel will monitor supervision messages sent by the KP-140 PG2 device. or Select between "Disabled", "Wall Only" or "Battery Only". Here you determine whether or not the tamper alarm will be activated and if so whether it will be a wall tamper alarm or a battery tamper alarm. 2 D-303015 PGM: Pressing the AUX button will activate the PGM output (for further programming instructions see the PowerMaster-10 Installer Guide section 4. 12 CONFIGURING OUTPUT PARAMETERS). When exiting "INSTALLLER MODE" menu, the PowerMaster-10 system displays the number of devices that need to be updated, as follows: "DEV UPDATING NNN". For detailed instructions on Adding Devices, Deleting Devices, Replacing Devices and Defining Defaults see the PowerMaster-10 Installer Guide. or Select between "Not Used", "Stop Beeps", "Skip exit delay" and "PGM". 6. OPERATION The tables in the following sections describe how to activate the various functions of the KP-140 PG2 keypad. Safety Function Emergency alarm Fire alarm Actions ( 2 sec. ) Security Function Actions Partition Selection (when Partition is enabled) Arming HOME Arming AWAY Disarming Quick arm / HOME Quick arm / AWAY Instant / / [user code] [user code] [user code] ( 2 sec. ) ( 2 sec. ) (perform HOME/ AWAY arming) (2) (1) ( 2 sec. ) Panic alarm ( 2 sec. ) Notes 1. For arming HOME/AWAY a specific Partition, first press the Partition number and then perform the arming action. For INSTANT arming function, press the HOME/AWAY button, enter the user code while the HOME/AWAY button blinks, wait for success acknowledgement (green LED lights and "happy" beep is heard), then press the INSTANT button. For LATCHKEY arming function by arming AWAY / quick arm away, wait for success acknowledgement (green LED lights and "happy" beep is heard), then press the AWAY button twice. Note: Immediately after performing arming AWAY of the system, you can perform the Latchkey and Instant functions, one after the other. The function of the AUX button can be configured on the control panel (see section 5. ) 5. The STATUS button has two functions; pressing Latchkey (perform arm AWAY) (3) Duress default) AUX Function Status [duress code] (2580 by (4) (5) Automation Function X-10 device ON Actions [X-10 no. 01 to 15] returns the KP-140 PG2 to idle mode from any the sequence, or, when the KP-140 PG2 is in idle mode, it displays the status of the control panel. Pressing the button, when the KP-140 PG2 is in idle mode, provides the status of the control panel and is indicated when / / button lights steadily and the LED the provides indication on the status of the control panel (see table below). ( / / ) lights steadily in parallel to the X-10 device OFF [X-10 no. 01 to 15] PGM device ON PGM device OFF PGM device toggle X-10 or status PGM device [00] [00] [00] [00 to 15] / / button and the LED provides indication on the status of the indicated partition no. D-303015 3 Control Panel Status Description LED lights green 4 sec. [. . . ] The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any telecommunication or electronic equipment or any programs. The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the Manufacturer's discretion any Product or part thereof that may prove defective. Any repair and/or replacement shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC KP-140 PG2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC KP-140 PG2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.