User manual TRIMBLE S SERIES TOTAL STATION V7.0 01-2010

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TRIMBLE S SERIES TOTAL STATION. We hope that this TRIMBLE S SERIES TOTAL STATION user guide will be useful to you.


TRIMBLE S SERIES TOTAL STATION V7.0 01-2010: Download the complete user guide (4391 Ko)

You may also download the following manuals related to this product:

   TRIMBLE S SERIES TOTAL STATION V4.00 2007 (2625 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 2008 (4503 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4750 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4809 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4518 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4535 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4523 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4821 ko)
   TRIMBLE S SERIES TOTAL STATION V6.00 11-2008 (4526 ko)

Manual abstract: user guide TRIMBLE S SERIES TOTAL STATIONV7.0 01-2010

Detailed instructions for use are in the User's Guide.

[. . . ] Trimble S Series Total Station ® User Guide F Version 7. 0 Part number 57127002 January 2010 Corporate Office Trimble Navigation Limited 645 North Mary Avenue PO Box 3642 Sunnyvale, CA 94085 USA Registration To receive information regarding updates and new products, please contact your local dealer or visit www. trimble. com/register. Upon registration you may select the newsletter, upgrade or new product information you desire. Notices The product option Panel BT Attachment Part Number: ® 58240001 contains a Bluetooth device with ID: QD ID B010797. Australia and New Zealand This product conforms with the regulatory requirements of the Australian Communications Authority (ACA) EMC framework, thus satisfying the requirements for C-Tick Marking and sale within Australia and New Zealand. [. . . ] Store correction Aim on target C >> New observation Change face Face-1 obs: 0 Face-2 obs: 0 >> New observation Change face Face-1 obs: 5 Face-2 obs: 5 C >> New observation Change face 6. Press A to scroll to one of the following: ­ ­ New observation. If you select New observation the number of observations in both faces appears: a. Aim accurately in face 2 towards a point at least 15 grads (13. 5 degrees) above or below the point where the collimation test was made at a minimum distance of 30 m (66 ft. ). b. Press C to measure and record angles. 52 Trimble S Series Total Station User Guide Setup 4 As observations are made on the first face (either face 1 or face 2), the angle values are stored and the observation counter increases. When one or more observations has been taken on each face, and the number of observations on each face are the same, the software calculates and displays the new trunnion axis tilt value. -Current valuesTrunnion: 0. 0003 >>Store correction Cancel C -AdjustmentsBack. . . Press A to scroll to one of the following: ­ Store correction. Then press C to return to the Adjustments menu. Note ­ The instrument will prohibit a trunnion axis tilt test if it is made towards a point with an angle less than 15 grads (13. 5 degrees) from the point where the collimation test was made. The trunnion axis tilt determination accuracy will improve with a steeper angle towards the measured point. The minimum distance for the trunnion axis tilt measurement is 30 m (66 ft. ). Note ­ If the trunnion axis tilt correction value is greater than 0. 05 grads (0. 045 degrees), the message Fail Remeasure?If the value is greater than 0. 05 grads (0. 045 degrees) and you answer No to the re measurement message, the instrument uses the correction value previously stored in the instrument. If the value is greater than 0. 05grads (0. 045 degrees), then the instrument must be mechanically adjusted at the nearest authorized Trimble service center. Autolock Collimation (Only on Instruments With Autolock Capability) The instrument tracker unit is designed to be coaxial with the instrument cross hairs. If for any reason the alignment of the tracker deviates from the line of the telescope cross hairs, then errors in position of the point being measured would result. For this reason an Autolock collimation check needs to be carried out on a regular basis (under the same conditions as the HA/VA collimation check) to ensure that any slight misalignment is corrected for. Trimble S Series Total Station User Guide 53 4 Setup Perform the test over a similar distance as that you will be working on, but at least 100 m. The prism target must be very still during the test (Trimble recommends that you use a tripod or bipod mount for the target) and must be in clear line of sight without any obstructing traffic. The instrument is calibrated to accurately point at the center of the target in both horizontal and vertical axes. The calibration is used to correct the positions of all points measured using the Autolock function. The measured calibration values are stored and used until a new set of calibration values are determined. Press A to scroll to Tracker collim then press C. -AdjustmentsBack. . . Laser pointer -Current valuesHA: 0. 0010 VA: 0. 0012 C >>Continue Cancel 2. [. . . ] . 1 2 Figure 7. 78 Attach Trimble CU to Trimble Robotic Holder 122 Trimble S Series Total Station User Guide Options & Accessories 7 Detaching a Trimble CU 70. 1 C Caution ­ Make sure to switch off the Trimble CU before it is detached from the instrument. 1. Push the lock release button on the bottom of the Trimble CU (1) and lift the bottom of the Trimble CU away from the holder (2). 2. Unhook the top of the Trimble CU from the top edge of the panel attachment and remove the Trimble CU from the holder (3), figure 7. 79. 3 2 1 Figure 7. 79 Detach Trimble CU from Trimble Robotic Holder Trimble S Series Total Station User Guide 123 7 Options & Accessories Attaching the Trimble Robotic Holder to the Rod 70. 1 To attach the Trimble Robotic Holder, slide the holder onto the standard rod adapter until the holder locks into place with a click, figure 7. 80. Figure 7. 80 Attaching the Trimble Robotic Holder to the standard rod adapter 124 Trimble S Series Total Station User Guide Options & Accessories 7 Detaching the Trimble Robotic Holder from the Rod 1. To detach the Trimble Robotic Holder from the rod, pull the release mechanism (1) 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRIMBLE S SERIES TOTAL STATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TRIMBLE S SERIES TOTAL STATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.