[. . . ] DATABASE DOCUMENTATION
HYDROpro Software
TM
Version 2. 40 Revision A October 2010
F
Trimble Navigation Limited Construction Business Area 5475 Kellenburger Road Dayton, Ohio 45424-1099 USA 800-538-7800 (toll free in USA) +1-937-245-5600 Phone +1-937-233-9004 Fax www. trimble. com E-mail: trimble_support@trimble. com Copyright and Trademarks © 20022010, Trimble Navigation Limited. For STL support, the software uses the Moscow Center for SPARC Technology adaptation of the SGI Standard Template Library. Copyright © 1994 Hewlett-Packard Company, Copyright © 1996, 97 Silicon Graphics Computer Systems, Inc. , Copyright © 1997 Moscow Center for SPARC Technology. Trimble, the Globe & Triangle logo, Geodimeter, and Terramodel are trademarks of Trimble Navigation Limited, registered in the United States Patent and Trademark Office and other countries. [. . . ] 0 = No, 1 = Yes.
VisualLinks The VisualLinks table is defined below.
Field VisualLinkId VisualLinkName FromVesselId FromOffsetId ToGOPointId ToVesselId ToOffsetId AnnotationPos ColorKey SpecifiedColor LinkLineStyle LinkLineWidth LinkVisible DependentStatus Description Unique internal visual link identification number. If the point status is selected, then link will be visible as specified. 0 = None, 1 = Surveyed, 2 = Up, 3 = Down.
Events Created on project creation.
Field TimeStamp Change IsCurrent EventConfigId Description Timestamp for tracking user changes. Internal reference ID number assigned to that particular configured event.
22
HYDROpro Software Database Documentation
Category
Specifies both the category (hundreds) and the sub-category (units). Categories: 000 = Interval, 100 = User, 200 = Log State, 300 = Guidance Object, 400 = Digital. Interval sub-categories: 0 = Time from Log On, 1 = Time from Start of GO, 2 = Distance from Log On, 3 = Distance from Start of GO. Guidance Object sub-categories: 0 = At Start of GO, 1 = At End of GO, 2 = At Waypoint, 3 = At Start of Leg, 4 = At End of Leg, 5 = At Start of Segment, 6 = At End of Segment. Digital sub-categories: 0 = Not Specified, 1 = Activate, 2 = Deactivate, 3 = Any. For position events, it is a unitless integer value in the range 1. . . max int. Internal reference number assigned to the Digital service used by Digital event.
LongEventName ShortEventName Active EventCodeType StartEventCode NextEventCode PrependGOName Increment SymbolId Indicator SteerbyId Interval Double EarlyEventMode EarlyEventAdjust EventAtStart EventAtEnd LeadinEvents RunOut OccursOutOfLimits AllowRerun NextEventMark CSId
EventActions Created on project creation. This table is independent of the user interface.
Field TimeStamp Change IsCurrent Description Timestamp for tracking user changes. 0 = No, 1 = Yes.
HYDROpro Software Database Documentation
23
Field ActionId
Description Action to be performed. Log Event Data (0), Annotate Echo Sounder (1), Auto Log On (2), Auto Log Off (3), Auto Toggle Logging (4), Next (5), Prior (6). Categories: 000 = Interval, 100 = User, 200 = Log State, 300 = Guidance Object, 400 = Digital. Interval sub-categories: 0 = Time from Log On, 1 = Time from Start of GO, 2 = Distance from Log On, 3 = Distance from Start of GO. Guidance Object sub-categories: 0 = At Start of GO, 1 = At End of GO, 2 = At Waypoint, 3 = At Start of Leg, 4 = At End of Leg, 5 = At Start of Segment, 6 = At End of Segment. Digital sub-categories: 0 = Not Specified, 1 = Activate, 2 = Deactivate, 3 = Any. Internal reference ID number assigned to that particular configured event. Internal reference number assigned for the service specified in the Annotate Echos Sounder or Digital actions. Internal reference ID number assigned to that particular configured echo sounder service or service group for the Annotate Echo Sounder or Digital actions. Echo sounder service Data Source for the Annotate Echo Sounder or Digital actions. Steer-by identifier used by the Annotate Echo Sounder or steer-by actions. [. . . ] The Output Format ID to use for the body, header, or footer format in the real-time report. Set to 0 if the body format has not been selected or if the selected output format is subsequently deleted. Continuous with header per file (0), Continuous with header per session (1), Paged (2). Maximum number of lines to print on a page, including optional header and footer. [. . . ]