[. . . ] With two fence nozzles, the system supports up to eight boom sections. You can disable both fence nozzles, enable either the left or right fence nozzle, or enable both. Enter the number of boom sections on your spray boom (not counting fence nozzles). You can select up to 10 boom sections, or up to eight if you have both fence nozzles enabled. [. . . ] Configure the following options:
Setting
Rate Control
Description
If you want the EZ-Boom system to control boom switching only, set Rate Control to Off: · If you set the Rate Control option to Off, the Off When Stopped option appears. · If you set the Rate Control option to On, the Rate 1, Rate 2, Allowable Error, Minimum Flow, and Rate Increment options appear. If the vehicle is a clutch-operated planter, select No so you can continue planting even when stopped. This is the volume that the sprayer supplies when the Rate switch is set to 1. This is the volume that the sprayer supplies when the Rate switch is set to 2. This is the percentage of acceptable Rate 1 or Rate 2 error before the flow control valve adjusts. When the Rate switch is in the Rate 1 or Rate 2 position, the current application rate increases or decreases by this amount each time you press the Rate adjustment (inc/dec) switch. When the Rate switch is in the Manual position, Rate Increment does not apply. The Rate adjustment (inc/dec) switch directly activates the valve; hold the switch up to increase or down to decrease.
Off Rate Control = On
Off When Stopped Rate 1 Rate 2 Allowable Error Rate Increment
3. Configuring the flow Control ValVe
Description
The flow control valve type: · If you select Inline Servo, Bypass Valve, or Pump Servo, the Response 1, Response 2, Threshold, and Close on Zero Flow options appear. · If you select PWM or Grounded PWM, the Close on Zero Flow, Frequency, Gain, and Zero Flow Offset options appear. The desired adjustment speed of the valve when the application rate is outside the threshold. The desired adjustment speed of the valve when the application rate is within the threshold. The point at which the application rate is close enough to the target rate for the application speed of the valve to switch from Response 1 to Response 2. The shut-off point of the PWM valve.
Inline/Bypass/Pump All PWM
Response 1 Response 2 Threshold
Close on Zero Flow Frequency Gain Zero Flow Offset
3. Press
to exit the Control Valve Setup screen.
www. EZ-Boom. com
EZ-BoomTM 2010 System for the EZ-Guide® 500 Lightbar Quick Reference Card
step 7. Configure the following options:
Setting
Capacity Current Volume Low Limit Tank Refill Method
Description
The capacity of the tank when full. The method that you will use to fill the tank: · Partial Refill = If you add a specific amount of solution to the tank. (If you select Partial Refill, the Partial Refill Quantity option appears). The amount that you add when you partially fill the tank.
Partial Refill Quantity
3. [. . . ] For a Raven flow meter, enter the calibration number as it is written on the tag. For other brands of flow meter, add a 0 to the number when you enter it (for example, if the number is 75, enter 750). Do one of the following: To exit the screen and use the flow meter calibration number, press . To fine tune the calibration, adjust the following settings:
Setting
Target Rate Speed Total Nozzles
Description
Set the expected application rate. [. . . ]