User manual TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET DATA SHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET. We hope that this TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET user guide will be useful to you.


TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET DATA SHEET: Download the complete user guide (527 Ko)

Manual abstract: user guide TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJETDATA SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Jitter and Eye-diagram Analysis Tools DPOJET Data Sheet DPOJET Essentials or Advanced Period, Frequency, and Time Interval Error Analysis Timing Parametrics such as Rise/Fall Times, Pulse Width, and Duty Cycle Many Graphical Tools such as Histograms, Time Trends, and Spectrums Programmable Software Clock Recovery including Software PLL*3 User-selectable Golden PLL Support for Popular Standards Selectable High- and Low-limit Measurement Bounds Test Comprehensive Statistics Logging, Reporting, and Remote Automation Capture and Save Worst-case Signals for Detailed Analysis TekWizardTM Interface for One-button and Guided Jitter Summaries Features & Benefits DPOJET Advanced Jitter and Timing Analysis for Clocks and Data Signals Real-time Eye-diagram (RT-EyeTM) Analysis*1 Selectable High- and Low-pass Measurement Filters Nine Plot Types to View and Analyze Jitter: Eye Diagram, CDF Bathtub, Spectrum, Histogram, Trend, Data, Phase Noise, and Transfer Function Accurate Jitter Decomposition and TJ(BER) Estimation*2 with Selectable Jitter Models Support Popular Standards; Fibre Channel or PCI Express Delta-Delta (Dual Dirac) and Convolved Results Full Pass/Fail Limits and Mask Testing with Comprehensive Standards Support Library; plus User Limit and Mask Files allows Support of Custom Test Configurations and New or Developing Standards Applications Characterize Performance of High-speed Serial and Parallel Bus Designs Characterize Clock and Data Jitter and Signal Integrity Characterize PLL Dynamic Performance Characterize Modulation of Spread Spectrum Clock Circuits Characterize Jitter Generation, Transfer, and Tolerance Perform PHY Testing of PCI Express, Serial ATA, SAS, Fibre Channel, MIPI, DisplayPort, DDR, DDR2, DDR3, LPDDR, LPDDR2, USB 3. 0, and other Electrical and Optical Systems *1 Patented USPTO #6, 836, 738 *2 Patented USPTO #6, 832, 172, #6, 853, 933, #7, 254, 168 *3 Patented USPTO #6, 812, 688 Data Sheet Real-time Jitter and Eye-diagram Analysis DPOJET is the premiere eye-diagram, jitter, and timing analysis package available for real-time oscilloscopes. Operating in the Tektronix DPO/DSA70000B, MSO70000, and DPO7000 Series oscilloscopes, DPOJET provides engineers the highest sensitivity and accuracy available in real-time instruments. [. . . ] DPOJET analysis plots, like Spectrum and Trend, go beyond simple measurements and results display. Trend analysis quickly shows engineers how timing parameters change over time, like frequency drift, PLL startup transients, or a circuit's response to power supply changes. Spectrum analysis quickly shows the precise frequency and amplitude of jitter and modulation sources for easy, rapid identification. Finding sources like adjacent oscillators and clocks, power supply noise, or signal crosstalk is no longer a tedious chore. Unique in the industry, DPOJET also provides Phase Noise plots to show jitter in root/Hertz and Transfer Function plots that allow direct comparison of jitter spectrums between two signals of differing frequencies, providing the perfect tool for determining jitter in PLL circuits like clock multipliers. With premiere measurement flexibility, oscilloscope model support, limit testing, results logging and reporting, and integrated remote programmability, DPOJET fully supports applications from device and system debug and characterization to short-run functional test and production. DPOJET Jitter and Eye-diagram Analysis Tools extend the capability of Tektronix real-time oscilloscopes, performing complex measurements and analysis of clock, serial, and parallel data signals captured in Single-shot Acquisition mode or in Continuous-run Acquisition mode. Providing jitter and timing measurements with pass/fail parameter testing, and eye 2 www. tektronix. com Jitter and Eye-diagram Analysis Tools -- DPOJET Characteristics Characteristic Description Physical Characteristics Jitter Noise Floor Jitter Measurement Accuracy 0. 4 psRMS (typical with DSA72004B) 1. 5 psRMS (typical with DSA72004B) Software is supplied on internal hard disk and on compact disk media, or can be downloaded from www. tektronix. com. Software installs and operates with DPO/DSA70000B, MSO70000, and DPO7000 Series oscilloscopes. Online documentation and printable manual in PDF format are supplied with the product. Recommended Accessories Ordering Information DPOJET Advanced Option DPO/DSA70000B, MSO70000, or DPO7000 Series Accessory Description Opt. DJAU DPOFL-DJA Order preinstalled on a new oscilloscope DPO7054, DPO7104, DPO7254, DPO7354 DPO70604B, DPO70804B DPO71254B, DPO71604B, DPO72004B DSA70000B Series MSO70000 Series, 4-8 GHz MSO70000 Series, >12 GHz Floating License Order an upgrade for existing oscilloscope: Opt. [. . . ] Information in this publication supersedes that in all previously published material. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX JITTER AND EYE-DIAGRAM ANALYSIS TOOLS DPOJET will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.