User manual SIMRAD SP90 REV E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMRAD SP90. We hope that this SIMRAD SP90 user guide will be useful to you.


SIMRAD SP90 REV E: Download the complete user guide (2713 Ko)

You may also download the following manuals related to this product:

   SIMRAD SP90 REV D (3018 ko)
   SIMRAD SP90 MINI MANUAL REV A (749 ko)

Manual abstract: user guide SIMRAD SP90REV E

Detailed instructions for use are in the User's Guide.

[. . . ] Operator manual Simrad SP90 Low frequency long range fishery sonar www. simrad. com MAXIMIZING YOUR PERFORMANCE AT SEA 850-164511 / Rev. E SP90 Low frequency long range fishery sonar Operator manual WARNING The sonar must never be powered up when the ship is in dry dock. To prevent inadvertent use of the sonar, pull out the mains plug on the Sonar Processor Unit whenever the vessel is in dry dock. About this document Rev Rev. E Date 17. 12. 04 Written by RBr Checked by OBG Approved by OBG Complies to software version 1. 2. X Added and changed parameter and maintenance details. © 2004 Simrad AS ISBN 82-8066-003-8 All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Simrad AS. The information contained in this document is subject to change without prior notice. [. . . ] All the functions - except Track history - are on/off buttons. Cosmetic parameters Slant Range / True Range, page 136 Bearing Card, page 52 Compass Card, page 53 Distance Rings, page 52 VRM (Variable Range Marker), page 53 Bow Marker, page 54 Track History, page 144 Minute Marker, page 54 Wind Marker, page 52 Vertical Ring, page 53 Depth dividers, page 54 The Close button closes this menu. The Help button opens the on-line help. 66 850-164511 / Rev. E Menu descriptions Store/Recall The Store/Recall menu is activated by the Store/Recall button in the Setup menu. The Store/Recall menu is used to store single display pictures or a sequence or pictures. The stored pictures can easily be recalled for evaluation or comparing schools. Store/Recall parameters Store - This is the "record" button to start the storage sequence. Print - Allows you to print the stored picture to the default printer (if any). The following other parameters are available: Store, page 140 Store Mode, page 140 Recall, page 128 Recall Mode, page 128 The Close button closes this menu. The Help button opens the on-line help. 850-164511 / Rev. E 67 Simrad SP90 System test The System test menu is activated by the Test button in the Setup menu. The System test menu provides several test routines available to perform operational and functional tests. These tests are designed only to be carried out by qualified service engineers. Test parameters Test Configuration - This function is only to be activated by qualified service engineers. Test Function - This function is only to be activated by qualified service engineers. Toggle TxPower - This function is only to be activated by qualified service engineers. Test Beam - This function is only to be activated by qualified service engineers. Echo Level - This button provides a readout of the current noise in the waters surrounding the vessel. This noise is caused by air bubbels, water flow and mechnical disturbances from hull and engine. In order to obtain the besst possible sonar result, the noise level readout should be as close to 0. 0 dB as possible. Roll - This is not a button, it is a readout from the sensor of the actual roll value at the time of the last transmission. Pitch - This is not a button, it is a readout from the sensor of the actual pitch value at the time of the last transmission. TRU Temp- This button provides a readout of the current temperature inside the Transceiver Unit. If the temperature rises to unacceptable levels, and alarm will be given. Interpolation - This is a built-in software function that may give a more realistic presentation of the echos. Message bar - This button opens the Message bar parameter dialogue, which allows you to monitor operational messages from the sonar. Installation menu - This button opens the Installation menu on the top of the display. [. . . ] Set the switch to STOP to position the transducer at any vertical location. Marine growth must be carefully removed with fine-grade sandpaper or emery paper. Note The transducer surface must not be painted. 164 850-164511 / Rev. E On-board maintenance Hoist motor overload protection To prevent the hoist/lower motor from overload, an overload circuit breaker S301 is located in the Motor Control Unit. This may automatically be switched off during hoisting if the vessel's speed is too high, or if the transducer shaft has been bent. To reset the motor overload switch, open the Motor Control Unit, locate the switch S301 and press the button marked 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD SP90




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD SP90 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.