User manual SIMA SED-2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMA SED-2. We hope that this SIMA SED-2 user guide will be useful to you.


SIMA SED-2 : Download the complete user guide (837 Ko)

Manual abstract: user guide SIMA SED-2

Detailed instructions for use are in the User's Guide.

[. . . ] Heed Warnings - All warnings on the appliance and in the operating instructions should be adhered to. Water and Moisture - the appliance should not be used near water - for example: near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement or near a swimming pool. Ventilation - The appliance should be located so that its location or position does not interfere with proper ventilation. For example: the appliance should not be situated on a bed, sofa, rug or similar surface that may block the ventilation openings. [. . . ] 7 - Optical and coaxial output for digital audio that connects to the digital audio input of stereo receiver. 8 - Left and Right audio outputs, A and B that connects to the audio inputs on your TV, VCR or surround sound receiver 9 - 15V DC input from the AC wall power supply 10 ­ DIP Switch setting to set the default operation of the unit. 11 - Wired IR Input connect to your home automation system or Sima SUR-47 Wireless LCD Touchscreen Remote Control 12 - SVS-CONTROL connect to your home automation system or PC. 13 ­ Left and Right Record audio outputs that connect to the input on your recording VCR/DVD. 14 - Composite and S - Video Record outputs that connect to the input on your recording VCR/DVD. 15 - S-Video and Composite Video View Output (A&B) that connects to your TV or monitor. 16 ­ Left and Right Component Video View output that connects to your TV or monitor Page 6 IR Remote Control, RM-18 Fig. 3, RM-18 The RM-18 IR remote control allows you to control all of the functions available from the unit's front panel, with the addition of a DIM setting. DIM - Pressing this button cycles through four levels of brightness on the front panel lights - bright, medium, dim or off. VOLUME STABILIZER ACTIVE - Toggles between the Volume Stabilizer being Active or in the Bypass mode. AUTO SCAN - Toggles between the Automatic Input Selection mode being on or off. If you are using a source with s-video then you must use an s-video connection to the recording VCR and to the television. Page 10 Operation When AC power is first applied, all outputs will be muted and all the lights will come on for 1 second and then go out. The Auto Input and Volume Stabilization modes will be active as default. When the unit detects an active video input (composite, SVideo, or component video), the Power / Standby light will turn off full and the active input will be selected. Power As long as AC power is not lost, the previous status (last selected input, Volume Stabilizer mode and AUTO SELECT status) will be resumed when Power / Stand-by is pushed. If AC power was lost, the unit will default with input #1 (both View and Record) selected, Volume Stabilization on and AUTO SELECT on. View Inputs Pushing a view input button on either the front panel or on the IR remote, will cause the view current input and associated LED to go off and the new input to come on. If the Auto Input Mode is on, the selected input will over ride the current input until another input is selected or another input is automatically detected. Record Inputs Pushing a record input button on the IR remote, will cause the current record input and associated LED to go off and the new input to come on. To set the record input from the IR remote control, first press the record button on the remote control, which will cause all of the record input LEDs to become lit. Within 3 seconds press the number of the input you wish to direct to the record output. Auto Select Mode If the Auto Select Mode is active, the unit will select a video signal from the View video inputs. If a second input becomes active, the VS-712EX will automatically change to the new input. If you want to go to another A/V source, simply select the input using the front panel button or the remote. If you don't want the VS-712EX to automatically select an active input, turn the AUTO SELECT mode off. Please note when you activate Auto Select Mode, it scans the inputs when the VS-712EX is on or in the standby mode. [. . . ] The received message structure is summarized in the following table: Start Character @ Address 0 1 2 3 Command S = Setup Sub-Command S = Standby A = Auto Select L = Loop protect R = Record follows play P = Front Panel Switches D = LED Dimmer E = Every signal C = Compander Data 0 = Off 1 = On 1 ­ 7 = Channel selection Any (next LED brightness step decreasing) 1 ­ 7 = Channel selection 0 = Off 1 = On U = Compander UP D = Compander Down Any 0 = Off 1 = On V = View R = Record C = Compander ?= Status Request D = Diagnostics Any D = Diagnostics Note that not all command / sub-command / data combinations are valid. See section 7. 4 for a summary of all valid commands. Page 18 Message Acknowledgement The VS-712EX will ignore any message that does not begin with the @ character. When the VS-712EX receives an correctly initiated RS232 message, it will respond with an acknowledgement message, followed by a block of data, as appropriate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMA SED-2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMA SED-2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.