User manual SIEMENS LB75564GB/04 INSTALLATION INSTRUCTIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIEMENS LB75564GB/04. We hope that this SIEMENS LB75564GB/04 user guide will be useful to you.


SIEMENS LB75564GB/04 INSTALLATION INSTRUCTIONS: Download the complete user guide (1822 Ko)

Manual abstract: user guide SIEMENS LB75564GB/04INSTALLATION INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

[. . . ] If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours. 3 Before using for the first time Important notes: The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. The appliance may be connected to the mains by a qualified technician only. [. . . ] Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. When cleaning the filters by hand, soak them in hot soapy water first of all. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Light Fan settings Setting the required fan speed: Press the corresponding button. Lighting: The light can be switched on at any time, even though the fan is switched off. 5 Filters and maintenance Removing and inserting the metal grease filters: 1. Press the catch on the grease filters inwards and fold the filters down. Remove the metal filters (see "Removing and inserting the metal grease filters"). Insert the metal grease filters (see "Removing and inserting the metal grease filters"). Insert the metal grease filters. Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Replacing the activated carbon filter: During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x year. A replacement filter can be obtained from any authorized dealer (see optional accessories). flying sparks) ­ unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood. Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e. g. Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 460 400 260 280 5 00 0 /90 600 The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Exhaust air may be discharged in accordance with official and statutory regulations only (e. g. Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. [. . . ] The bottom edge of the template equates to the lower edge of the extractor hood. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Note: Take into account any special accessories that are going to be fitted. Attach the 2 enclosed spacers to the fixing bracket for the flue duct panelling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS LB75564GB/04




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS LB75564GB/04 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.