User manual PANASONIC S-140PF1E5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC S-140PF1E5. We hope that this PANASONIC S-140PF1E5 user guide will be useful to you.


PANASONIC S-140PF1E5 : Download the complete user guide (2377 Ko)

You may also download the following manuals related to this product:

   PANASONIC S-140PF1E5 (2606 ko)
   PANASONIC S-140PF1E5 (2563 ko)
   PANASONIC S-140PF1E5 (2561 ko)
   PANASONIC S-140PF1E5 (2517 ko)
   PANASONIC S-140PF1E5 (2512 ko)
   PANASONIC S-140PF1E5 (2391 ko)
   PANASONIC S-140PF1E5 (2396 ko)
   PANASONIC S-140PF1E5 (2388 ko)
   PANASONIC S-140PF1E5 (2390 ko)

Manual abstract: user guide PANASONIC S-140PF1E5

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions Air Conditioner * Shows U1 type (4-Way Cassette) Model No. Indoor Units 4-Way Cassette S-36PU1E5 S-45PU1E5 S-50PU1E5 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5 Indoor Units Low Silhouette Ducted S-36PF1E5 S-45PF1E5 S-50PF1E5 S-60PF1E5 S-71PF1E5 S-100PF1E5 S-125PF1E5 S-140PF1E5 Outdoor Units Single Split (Single-phase) ?U-60PE1E5 U-71PE1E5 U-100PE1E5 U-125PE1E5 U-140PE1E5 * Shows F1 type (Low Silhouette Ducted) (3-phase) ?U-71PE1E8 U-100PE1E8 U-125PE1E8 U-140PE1E8 ENGLISH 2 ~ 13 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. [. . . ] When the air conditioner is turned off, the flap (vertical airflow flap) automatically moves to the downward position. The flap (vertical airflow flap) moves to the upward position when performing the standby operation for heating. The swing operation is made after the standby operation for heating is released, but swing is indicated on the remote controller even during the standby operation for heating. FLAP button is pressed during operation. Setting the airflow direction To activate the swing operation The airflow direction changes each time the Press the FLAP button to set the flap (vertical airflow flap) to the downward position, and then press the FLAP button again. Cooling and drying The flap (vertical airflow flap) can be set to one of three positions. Heating Set the flap (vertical airflow flap) to the downward position. If the flap is set to the upward position, the warm air may not reach the floor. Fan operation All operations Initial setting Initial setting Initial setting Continuous operation To stop the swing operation Press the FLAP button again during the flap swing operation to stop the flap at the desired position. Then, the airflow can be set from the top position by pressing the FLAP button again. Indicator when swing operation is stopped Fan and heating Cooling and drying During cooling or drying operation, the flap will not stop at the downward position. Even if the flap is stopped at the downward position during the swing operation, it will not stop until it moves to the third position from the top. 8 01_F568247_EN. fm Page 9 Thursday, November 17, 2011 8:55 PM ADJUSTING AIRFLOW DIRECTION (CONTINUED) U1 type air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller. After washing with water, allow it to dry, and then remount it with the arrow facing outward. Concealed duct type (F1) This air conditioner is not equipped with air outlet parts. Please refer to the manual of the locally adopted air outlet parts. 9 01_F568247_EN. fm Page 10 Thursday, November 17, 2011 8:55 PM ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) ?The airflow direction cannot be set using the remote controller for the concealed duct type (F1). If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below). Set the airflow direction for the indoor unit that is shown on the display. Each time UNIT is pressed, the indicator changes in the order shown below. When nothing is displayed, you can make the setting for all indoor units in one operation. The unit number is displayed as Outdoor Unit Number?Indoor Unit Number. 1?3 10 01_F568247_EN. fm Page 11 Thursday, November 17, 2011 8:55 PM SPECIAL REMARKS ??DRY??Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. operation is not possible if the outdoor temperature is 15 C or less. Heating Operation Heating performance ? [. . . ] is sometimes operating for a while even though outdoor compressor is stopped. 12 01_F568247_EN. fm Page 13 Thursday, November 17, 2011 8:55 PM CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Press ON/OFF operation button on remote control unit again. If breaker has been tripped, consult your dealer without turning it on. Air conditioner does not run at Power failure or after power failure all although power is turned on. Poor cooling or heating performance If blown out, consult your dealer. Air intake or air discharge port of indoor Remove dust or obstruction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S-140PF1E5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S-140PF1E5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.