User manual PANASONIC S-100PT1E5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC S-100PT1E5. We hope that this PANASONIC S-100PT1E5 user guide will be useful to you.


PANASONIC S-100PT1E5 : Download the complete user guide (2325 Ko)

You may also download the following manuals related to this product:

   PANASONIC S-100PT1E5 (3297 ko)
   PANASONIC S-100PT1E5 (2489 ko)
   PANASONIC S-100PT1E5 (2490 ko)
   PANASONIC S-100PT1E5 (2443 ko)
   PANASONIC S-100PT1E5 (2435 ko)
   PANASONIC S-100PT1E5 (2339 ko)
   PANASONIC S-100PT1E5 (2335 ko)
   PANASONIC S-100PT1E5 (2340 ko)
   PANASONIC S-100PT1E5 (2346 ko)

Manual abstract: user guide PANASONIC S-100PT1E5

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions Air Conditioner * Shows T1 type (Ceiling) Model No. Indoor Units 4-Way Cassette 6060 (Y1 type) S-36PY1E5 S-45PY1E5 S-50PY1E5 Indoor Units Wall Mounted (K1 type) S-36PK1E5 S-45PK1E5 S-50PK1E5 S-60PK1E5 S-71PK1E5 Indoor Units Ceiling (T1 type) S-36PT1E5 S-45PT1E5 S-50PT1E5 S-60PT1E5 S-71PT1E5 S-100PT1E5 S-125PT1E5 S-140PT1E5 Outdoor Units Single Split (Single-phase) U-60PE1E5 U-71PE1E5 U-100PE1E5 U-125PE1E5 U-140PE1E5 U-100PEY1E5 U-125PEY1E5 (3-phase) U-71PE1E8 U-100PE1E8 U-125PE1E8 U-140PE1E8 U-100PEY1E8 U-125PEY1E8 ENGLISH 2 ~ 13 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. FRANAIS 14 ~ 25 Avant d?utiliser l?appareil, lisez ce mode d?emploi dans son intgralit et conservez-le pour toute rfrence ultrieure. ESPAOL 26 ~ 37 Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y gurdelas para futuras consultas. [. . . ] FLAP button is pressed during operation. Setting the airflow direction To activate the swing operation The airflow direction changes each time the Press the FLAP button to set the flap (vertical airflow flap) to the downward position, and then press the FLAP button again. Cooling and drying The flap (vertical airflow flap) can be set to one of three positions. Heating Set the flap (vertical airflow flap) to the downward position. If the flap is set to the upward position, the warm air may not reach the floor. Fan operation All operations Initial setting Initial setting Initial setting Continuous operation To stop the swing operation Press the FLAP button again during the flap swing operation to stop the flap at the desired position. Then, the airflow can be set from the top position by pressing the FLAP button again. Indicator when swing operation is stopped Fan and heating Cooling and drying During cooling or drying operation, the flap will not stop at the downward position. Even if the flap is stopped at the downward position during the swing operation, it will not stop until it moves to the third position from the top. 8 01_85464609176012_EN. fm Page 9 Wednesday, October 3, 2012 1:49 PM ADJUSTING AIRFLOW DIRECTION (CONTINUED) Y1 type air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller. After washing with water, allow it to dry, and then remount it with the arrow facing outward. Ceiling mounted type (T1) Vertical directions (automatic) This air conditioner is equipped with an auto flap. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller. (Refer to the description of the remote controller. ) Do not move the flap with your hands. Horizontal directions (manual) The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right. Wall mounted type (K1) Vertical directions (automatic) Confirm that the remote controller has been turned on. If you want to stop the flap movement and to direct the air in the desired direction, press the FLAP button again. In the cool mode, do not direct the flap down and move out of the cooling zone ?A?, otherwise, condensation may drip on to the floor. When operating continuously in the fixed airflow direction setting for about an hour, the airflow direction is automatically controlled and the flap position is changed. The airflow direction may be different from the display on the remote controller. for heating Indoor unit Horizontal directions (manual) The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right. 9 01_85464609176012_EN. fm Page 10 Wednesday, October 3, 2012 1:49 PM ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) ?If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below). Set the airflow direction for the indoor unit that is shown on the display. Each time UNIT is pressed, the indicator changes in the order shown below. When nothing is displayed, you can make the setting for all indoor units in one operation. The unit number is displayed as Outdoor Unit Number?Indoor Unit Number. 1?3 10 01_85464609176012_EN. fm Page 11 Wednesday, October 3, 2012 1:49 PM SPECIAL REMARKS ??DRY??Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. [. . . ] is sometimes operating for a while even though outdoor compressor is stopped. 12 01_85464609176012_EN. fm Page 13 Wednesday, October 3, 2012 1:49 PM CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Press ON/OFF operation button on remote control unit again. If breaker has been tripped, consult your dealer without turning it on. Air conditioner does not run at Power failure or after power failure all although power is turned on. Poor cooling or heating performance If blown out, consult your dealer. Air intake or air discharge port of indoor Remove dust or obstruction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S-100PT1E5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S-100PT1E5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.