User manual NAPCO MAGNUM ALERT 850 SYSTEM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO MAGNUM ALERT 850 SYSTEM. We hope that this NAPCO MAGNUM ALERT 850 SYSTEM user guide will be useful to you.


NAPCO MAGNUM ALERT 850 SYSTEM : Download the complete user guide (486 Ko)

Manual abstract: user guide NAPCO MAGNUM ALERT 850 SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] The three reminders ("DISABLE"; "FIRE/TEL"; "SYS TBL") will display and all screen characters will appear black. Holding the [] key depressed, press [3] to view different FIRE TROUBLE RESET characters on the display. Press [NO] to continue to scroll options or [YES] To test fire alarm signal devices, enter code and press to select option. SUPERVISORY ALARM The keypad will sound and display "SUPV ALARM" followed by the number and description of the fire supervisory SYSTEM TROUBLE zone in alarm, then "FIRE STATUS", then "SPRINK SUPV When a system trouble is detected, the "SYS TBL" reminder ALARM". [. . . ] The keypad will silence and SUPERVISORY TROUBLE the system trouble descrIption will clear. However If the system The keypad will sound and display "SUPV TROUBLE" trouble still exists, the "SYS TEL" reminder will remain on and followed by the number and description of the supervisory zone the screen will display "NOT NORMAL". in trouble, then "FIRE STATUS", then "SPRINK SUPV To determine the particular condition responsible for the TRBL". Enter code and press [INFO]. The keypad will display options one at a time. Press [NO] to continue to scroll options or [YES] to select option. Local Service Representative: ________________________________________________________ Address: _________________________________________________________________________ Telephone Number: ________________________________________________________________ Note: (1) Test system weekly!(3) A complete functional checkout of the control unit is required following any programming or reprogramming. (4) This page is to be framed and mounted adjacent to the control unit. WI658C 08/99 BASIC OPERATING INSTRUCTIONS FOR THE MA3000 FIRE CONTROL PANEL WITH THE RP3000LCD KEYPAD. Note: Text in quotes indicates a displayed message; messages preceded and followed by asterisks indicate additional related message(s) to follow. Buttons markings are shown in brackets ( [ ] ). STANDBY There are two normal standby conditions for the fire system: Disarmed and Armed. In Normal Disarmed Standby, the keypad will display "SYSTEM READY" with the green STATUS light on (no Burglary Zones faulted) or `ZONE FAULT" with no lights on (a Burglary Zone is faulted). No reminders ("BYPASS"; "FIRE/TBL"; "SYS TBL") will be on. Another alarm will sound the signals Signal devices (bells, horns, etc. ) will not sound. The keypad will sound and display "SUPV ALARM" followed by the number and again. description of the zone in alarm, then "FIRE STATUS", then FIRE ALARM RESET "SPRINK ALARM". This indicates that a device designed to monitor Enter code and press [RESET]. To reset a sprinkler supervisory after a brief delay, the "FIRE/TBL" reminder should clear and the alarm, enter code and press [RESET]. To recall a sprinkler supervisory keypad display should return to "SYSTEM READY" with the green zone still in alarm. STATUS light on (no Burglary Zones faulted) or "ZONE FAULT" with 1. Press [FUNCTION] until "DISPLAY FIRE ALM" appears, then To reset the initiating device (clear smoke from the smoke detector, press [YES]. Recheck the devices indicated (reset pull station, wait for smoke DEVICES" displays, then press [YES]. If the "FIRE/TBL" reminder to clear from smoke detector, etc. ). [. . . ] does not clear, use the following procedure to identify the zones still in 4. Press [FUNCTION] until "DISPLAY FIRE ALM" appears, then The keypad will display "SUPV TRBL" followed by the zone press [YES]. Recheck the devices indicated (wait for smoke to clear from supervisory trouble, enter code and press [RESET] The keypad will smoke detector, etc. ). However, if the trouble still exists, "FIRE STATUS" will continue to scroll "SPRNK SUPVTRBL". [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM ALERT 850 SYSTEM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM ALERT 850 SYSTEM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.