User manual KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL. We hope that this KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL user guide will be useful to you.


KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL : Download the complete user guide (566 Ko)

Manual abstract: user guide KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL

Detailed instructions for use are in the User's Guide.

[. . . ] NEVER direct the laser beam at people or animals. NEVER look directly into the laser beam. · Do NOT direct the laser beam at strongly reflective materials, for example, mirrors. · Exercise particular caution if you wear contact lenses or spectacles or are using a light-bundling device such as a magnifiying glass. [. . . ] · Should a battery be accidentally swallowed, IMMEDIATELY seek medical assistance! Items supplied 1 x Laser Spirit Level 1 x Tripod-Stand 2 x 1. 5 V Batteries Type AAA/Micro 1 x Operating instructions Description of the appliance q Spirit level for vertical measurements w Spirit level for horizontal measurements e On/Off switch for spirit level illumination r On/Off switch for laser beam t Laser beam exit opening y Measurement scale u Ball and socket joint with retaining screw i Tripod-Stand with telesopic legs o 2 Retaining magnets integrated in the housing a Batteries s Battery compartment screw fixings -4- Technical Data Spirit level: 2 integrated bubble glasses, illuminated Power supply: 2 x 1. 5 V Type AAA/Micro Laser class: 2 Max. output power (P. max): < 1 mW Wave length (): 650 nm according EN60825-1:2007 Unpacking · Check that all items listed are available and that they show no signs of visible damage. · Remove all parts from the packaging and all packaging remnants from the items. · Retain the packaging, either for storing the appliance or for reuse in the event of posting it to Customer Services for repair. Inserting the batteries · Remove the battery compartment screws s and insert the two batteries a 1. 5 V Type AAA/Micro as shown in the illustration. The appliance is now ready for use. -5- Placement · Two retaining magnets o have been integrated on the underside of the laser spirit level to secure the appliance onto steel surfaces. · If you wish to use the tripod-stand i, screw these firmly onto the appliance underside. · Align the laser spirit level at its desired location so that, in the two spirit levels q and w, the air bubbles lie precisely between their respective markings, the laser spirit level is then positioned exactly level in all directions. A ball and socket joint with retaining screw u is available for this on the tripod stand. To level out floor/ground irregularities, the telesopic legs i on the tripod stand can be drawn out to varying lengths. Utilisation Attention!! This appliance contains a Class 2 laser. NEVER direct the laser beam at people or animals. NEVER look directly into the laser beam. · Press the On/Off switch r for the laser. When the appliance is correctly aligned in all directions, as described on Page 6, there now appears a red laser line r on the wall it is directed at, a line which is level with the floor/ ground. If the laser spirit level is standing on a level floor/the ground without the tripod stand, the vertical distance of the laser line from the base level amounts to 29, 5 mm. In darkened light conditions the spirit levels q and w now glow lightly. · For simple length measurements a measuring scale y is printed onto the side of the laser spirit level. -6- Cleaning and Maintenance To avoid the risk of eye damage: · Remove the batteries before cleaning the appliance. This will prevent the laser beam from being accidently switched on during cleaning. Cleaning the appliance: · Clean the appliance parts only with a dry or lightly moistened cloth. To avoid damage to the upper surfaces, do not use abrasive or aggressive cleaning agents. · If soiling is visible in the laser beam exit opening t, this should be carefully removed with a cotton stick. Maintenance · NEVER open any of the parts of the appliance. No form of maintenance, either on or in the appliance, is intended for execution by the user. [. . . ] · , . : · ( ) , / , . · / , ! 1 x 1 x 2 x 1, 5 V AAA/Micro 1 x q w e / r / t y u i o 2 a s - 12 - : : : . (P. max): (): 2 , 2 x 1, 5 V AAA/Micro 2 < 1 mW 650 nm EN60825-1:2007 · , . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KOMPERNASS POWERFIX KH 4179 LASER SPIRIT LEVEL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.