User manual ITS TELECOM CGW-I INSTALLATION V3.18 RELEASE 1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ITS TELECOM CGW-I. We hope that this ITS TELECOM CGW-I user guide will be useful to you.


ITS TELECOM CGW-I INSTALLATION V3.18 RELEASE 1: Download the complete user guide (857 Ko)

Manual abstract: user guide ITS TELECOM CGW-IINSTALLATION V3.18 RELEASE 1

Detailed instructions for use are in the User's Guide.

[. . . ] CGW-I Installation and Operation Guide Version 3. 18 Release 1 April 2009 CGW-I Cellular Gateway BRI-GSM Interface Installation and Operation Manual VERSION 3. 18 ED. 1 APRIL, 2009 NOTICE No part of this document may be reproduced or transmitted in any form or by any means (electronic, photocopying, recording, or otherwise) without the prior written permission of ITS. The trademark and service marks of ITS, including the ITS mark and logo, are the exclusive property of ITS, and may not be used without permission. All other marks mentioned in this material are the property of their respective owners. [. . . ] Go to the folder you are creating the device then click the New Device button. Enter the following parameters: Field Device Name Modem Phone Number IP Address Port Number Representative Name Representative Phone Parameter Name of your device Phone number if connecting to the device with a modem IP Address of your device Port Number of your device Contact person responsible for this device Phone number of the contact person responsible for this device To delete a device or folder: 1. Select the folder or device you want to delete then click the Delete button. If you are deleting a folder that has devices, you will see a warning that they will all be deleted. If you click Yes to delete it, the folder and all its contents are erased from the database. To edit a folder name: 1. Change the name of the folder and click OK. To edit a device's details: 1. Change the details of the device and click OK. CGW-I Cellular Gateway BRI-GSM : Installation and Operation Manual 24 Network Settings If your CGW-I device is connected to the network, the Network Settings window lets you define its address so that you can communicate with it remotely over TCP/IP. Field IP Address Subnet Mask Gateway IP Address Port Parameter IP Address of your device in the network Subnet Mask of your device in the network IP Address of the network gateway Port used by your device Reading Current Parameters To download all configuration parameters from the connected CGW-I, select: Communication Read Parameters, then click OK to read the parameters. Notes: You must be connected to the device to read parameters. A password must be entered before you can read parameters for the first time (default=1234) during a connection to a specific CGW-I device. It is recommended that you change the password. A gray bar will show the loading progress, followed by a message indicating whether the action was successful or not. If it was, the different CGW-I Manager screens now display all the current parameters of the connected CGW-I. Sending Current Parameters You can make changes to the parameters offline, without being connected to the device, but they will not be uploaded until you are connected. If you are connected and click the Apply button, any changes you have made on the open screen are sent to the device if you are connected. To upload the configuration parameters that you may have changed and are currently displayed on the different CGW-I Manager screens, select: Communication Send Parameters. Note: You must be connected to the device to send parameters. A password must be entered CGW-I Cellular Gateway BRI-GSM : Installation and Operation Manual 25 the first time you make a connection to a specific CGW-I device before you can upload parameters to it. A gray bar will show the sending progress, followed by a message indicating whether the action was successful or not. Setting a Password A password must be filled in before reading or sending parameters. To change the administrator's password: 1. A message will appear indicating if the Password has been changed successfully or not. CGW-I Cellular Gateway BRI-GSM : Installation and Operation Manual 26 3. 4. System Menu The System menu lists the following options for configuring your CGW-I. · · · · · · ISDN Setting System Settings Channel Settings System Operation Prepaid Settings Control The following sections describe each option and the windows that they open. ISDN Settings The ISDN Settings window lets you set the parameters of the ISDN connection to your CGW-I device. Enter the following parameters: Field Connection Type Operation Mode TEI Value Parameter Select the BRI interface: NT or TE. Enable when synchronization is done by another device which connects to the Synch-In port of the CGW-I. Disable when the CGW-I connects to a TE interface or the CGW-I Synch-In port is not used. For more details on external synchronization, see page 10. External Synchronization CGW-I Cellular Gateway BRI-GSM : Installation and Operation Manual 27 Field ISDN Version Parameter Select current ISDN-BRI version. Choose from: · Euro-ISDN (default) · Euro-ISDN ­ In Bound DTMF Dialing · Euro-ISDN ­ France · 1TR6 ­ Germany · Euro-ISDN ­ Germany System Settings The System Settings window lets you set the parameters for calls going through your CGW-I device. Enter the following parameters: Field Call Barring Dial Tone to PBX Call Duration Limitation Parameter Prevents SIM from accepting incoming calls or outgoing calls. [. . . ] Enter the name of the new or existing CDR file, then select the directory if it is not the default CGW-I directory. Click OK to view the file. CGW-I Cellular Gateway BRI-GSM : Installation and Operation Manual 45 To clear the current CDR: Select Report CDR Clear CDR. The CDR Records are deleted from the CGW-I device's memory System Alarms The System Alarms window lets you define what alarms the CGW-I device should trigger and where to send notification. Alarm notifications apply to the device and both SIM cards, where applicable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ITS TELECOM CGW-I




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ITS TELECOM CGW-I will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.