User manual HITACHI CMP401XU

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HITACHI CMP401XU. We hope that this HITACHI CMP401XU user guide will be useful to you.


HITACHI CMP401XU : Download the complete user guide (11690 Ko)

Manual abstract: user guide HITACHI CMP401XU

Detailed instructions for use are in the User's Guide.

[. . . ] HITACHI cannot assume liabilities for damage caused by mistake in installation or mounting, misuse, modification or a natural disaster. Note for Dealers: After installation, be sure to deliver this manual to the customer and explain to the customer how to handle the product. ENGLISH IMPORTANT SAFETY INSTRUCTIONS SAFETY POINTS YOU SHOULD KNOW ABOUT YOUR HITACHI PLASMA MONITOR Our reputation has been built on the quality, performance, and ease of service of HITACHI Plasma monitor. To help you operate these products properly, this section illustrates safety tips which will be of benefit to you. Please read it carefully and apply the knowledge you obtain from it to the proper operation of your HITACHI Plasma monitor. This will enable HITACHI to notify you promptly in the improbable event that a safety problem should be discovered in your product model. [. . . ] * Depending on the signal, satisfactory adjustment may not be possible in some cases. Use the and SELECT buttons to select the item to be adjusted and then use the and ADJUST buttons to adjust (example: Contrast). Independent Operation of Multiple Monitors (ID No) Setting the ID No. of the remote control allows separate control of up to a maximum of seven monitors. The number will be incremented (2 6 7 1 2) when this button pressed continuously. The remote control ID no. can be checked by pressing the ID SET button while holding down the ID button. ID Number Monitor [1] R/C [1] Contrast Next / Prev + 31 Adjust Return · Press the RETURN button to return to the previous screen. · If there is no operation for a period of one minute, the Adjustment Menu screen will be closed automatically. Monitor ID no. Remote control ID no. The ID remote control is operated by pressing the various buttons while holding down the ID button; Operation is possible only when the remote control and monitor ID nos. are the same. · The remote control can be operated normally by pressing the various remote control buttons without holding down the ID button. of Function MENU. OPERATING INSTRUCTIONS (continued) PICTURE MENU MENU Picture Audio Timer Function Setup Language Select OK Set OK Picture Contrast Brightness Color Tint Picture Enhancement Color Temperature Color Temp. Adjust Reset Select OK Set : : : : : : + 31 ­ 31 0 + 31 Off Normal Reset Return OK Contrast Next / Prev + 31 Adjust Return Picture Contrast Brightness Color Tint Picture Enhancement Color Temperature Color Temp. Adjust Reset Select OK Set : : : : : : + 31 ­ 31 0 + 31 Off Normal Reset Return OK Color Temperature Next/Prev Select Normal Return Picture Contrast Brightness Color Tint Picture Enhancement Color Temperature Color Temp. Adjust Reset OK Set Select : : : : : : + 31 ­ 31 0 + 31 Off Normal Reset Return OK Picture Color Temp. Adjust Amplitude Red ­ 63 Green 0 Blue ­ 31 Cut Off Red + 31 Green 0 Blue + 31 Reset Select On/Off On Reset Return Selected characters Setup hint Adjust for maximum visibility to suit the ambient brightness. This can adjust further till [+40] by pressing and holding cursor button at [+31]. The color for [+32] to [+40] numbers will change from white to magenta. Off Off Split Panoramic Reset Return OK MENU Function Panel Life Mode Display ID Number Inverse Standby White Gamma Reset Select Set Normal Off 1 On 60Min. Off 2. 2 Reset Return Selected characters Setup hint Screen Saver Off 60Min. 5Min. 20Min. This moves the picture around the screen in small amounts, at set intervals, to reduce the panel image retention. This is where stationary objects, such as screen logos, leave a slight image visible after they should have disappeared. This is used to reduce the panel image retention that can occur with stationary pictures by the white field signal. Press the MENU or RETURN button on the remote control to return to normal viewing. This turns the gray sidebars On/Off when watching normal mode screen size area. Optional (grayed out) Optional (grayed out) Optional (grayed out) Screen Wipe On 60Min. Black Side Panel Video Power Save Freeze Mode Default Zoom Reset (off the function) Off On (waiting to reset) The original factory settings for the items of this Menu page can be restored by pressing the OK button. This function is to suppress the contrast of the screen regardless of the Contrast setting in the Picture Menu. By this control, power consumption can be reduced or degradation of a panel can be mitigated. If the Contrast setting is changed when this item is set to Extend 1 or 2, it will be changed to Normal automatically. [. . . ] This should correspond to the signal mode of the signal from the equipment that is connected to AV2 video input terminal. This step should be set only when [Composite/Component] is selected on the 1st step. · If the signal from the equipment that is connected to AV4 Scart input terminal is S. Video or Composite, set this to correspond to that signal. · If the signal is RGB, it will be automatically recognized and this setting will have no effect. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI CMP401XU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HITACHI CMP401XU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.