[. . . ] EJB Series Enclosures
EJB Enclosures
Stainless Steel
Increased Safety Exe Dual Certified ATEX / IECEx
19
FACE A Z Y
Technical Data
V T
INT / EXT EARTH X FACE C
V
MAXIMUM QUANTITY OF ENTRIES PER FACE
Thread Size Box Type M16 M20 M25 M32 M40 M50 EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB 1 2 1 2 1 2 1 2 1 2 1 2 Face A / C 6 10 6 8 3 3 2 3 2 2 0 1 Face B Face D 4 6 8 10 4 6 6 8 2 3 2 3 1 2 2 3 1 2 2 2 0 0 1 1
Increased Safety II 2 GD Exe II C Gb Extb, III C Db. [. . . ] Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. Temperature Class and Ambient: T6 40°C, optional T5 with ambients up to 65°C. For full technical specification, see Page 32
Dimension S T V W X Y Z EJB1 Size (mm) 120 2 80. 5 96 126 96 148 EJB2 Size (mm) 150 2 90. 5 126 156 126 178
FACE D W
Terminal Type
Conductor Size (mm2) Min. EJB 1 EJB 2 12 12 10 7 6 1 1 18 18 15 11 9 7 Amps EJB 1 15 15 20 28 38 21 26 EJB 2 13 13 18 24 34 47 Reduced Terminal Content at Max. Amps EJB 1 EJB 2 EJB 1 EJB 2 9 9 8 6 5 11 11 10 8 6 17 17 22 29 40 17 17 22 29 40 -
WDU 2. 5N WDU 2. 5 WDU 4 WDU 6 WDU 10 WDU16 BK 6 MK 6/6
0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 1 1
420 550 690 550 550 550 275 420
HTB 6
0. 5
2 x 10mm2 550 3 x 6mm2 4 x 4mm2 4 x 0. 5mm2(Min) See certificate for more options
1
1
Max. Conductor Amps per Conductor Amps per Size mm2 Size mm2 Pillar Pillar 1 0. 5 1 0. 5 1 0. 75 1 0. 75 8 1 8 1 10 1. 5 10 1. 5 15 2. 5 15 2. 5 21 4 21 4 26 6 26 6 37 10 37 10
N/A
1
Notes:
For Junction Box Wattage Factor and Combined Terminal Resistance, see Pages 43 & 44 The box is supplied with an integral internal / external earth stud assembly. [. . . ] The terminals listed are restricted to a minimum operating temperature of -50°C.
Connection Solutions
HPG01
www. ehawke. com [. . . ]