User manual GRACO TWISTORK 308656F

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO TWISTORK. We hope that this GRACO TWISTORK user guide will be useful to you.


GRACO TWISTORK 308656F: Download the complete user guide (192 Ko)

Manual abstract: user guide GRACO TWISTORK308656F

Detailed instructions for use are in the User's Guide.

[. . . ] D Read all instruction manuals, tags, and labels before operating the equipment. D Do not exceed the maximum working pressure of the lowest rated component in your system. D Use fluids and solvents that are compatible with the equipment wetted parts. D Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer. [. . . ] D Always shut off the agitator and disconnect the air line before you remove the agitator from the drum or check or repair any part of the agitator. TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled. When flushing the air motor or pump, keep your face away from the exhaust port. 308656 3 Installation Grounding WARNING FIRE AND EXPLOSION HAZARD This unit must be grounded. Before you operate it, ground the system as explained in this section. For further grounding information, read the Grounding section in the pump manual and the agitator manual. To reduce the risk of static sparking, and all electrically conductive objects or devices in the dispensing area must be properly grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. To ground the dispenser, connect the end of the ground wire (4) to a true earth ground. See the Parts Drawing on page 6. NOTE: This unit is shipped with the ground wire attached to the grounding strip on the pump and to the grounding lug on the agitator. The ground wire must always be attached to these two places during use. WARNING TIPPING HAZARD This unit should be used only on flat, level surfaces. When the unit is mounted in the bung hole, the center of gravity is too high for stability during transfer and could tip over. If possible, before you tighten the bung connection, rotate the unit so the agitator air motor is as close as possible to the center of the drum. That will improve the center of gravity and reduce the tipping hazard. Operation Pressure Relief Procedure See the Parts Drawing on page 6. NOTE: The pump was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the pump with a compatible solvent before using the equipment. D You must ensure that the agitator is stopped any time it is not contained in the drum. See the pump manual and the agitator manual for detailed operating instructions. NOTE: For stopping the pump and agitator in emergencies, disconnect the air line from the quick-disconnect air line fitting (14). D When you lift the unit from the bung-mounted position, lift the unit with the aid of an overhead hoist hooked up to the lift hook (9). WARNING PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray, or splashing fluid, follow this procedure whenever you: D D D D Are instructed to relieve pressure Stop dispensing Check, clean, or service any system equipment Install or clean dispensing nozzles 1. Open the dispensing valve to relieve all fluid pressure, and have a container ready to catch the drainage. 4 308656 Service See the individual component instruction manuals for service instructions specific to the agitator and the pump. CAUTION Before operation, tighten the bung connection firmly by hand, and check it periodically during operation for tightness. [. . . ] This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non­Graco component parts. FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées. Graco Information For the latest information about Graco products, visit www. graco. com. TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you: Phone: 612­623­6921 or Toll Free: 1­800­328­0211 Fax: 612­378­3505 All written and visual data contained in this document reflect the latest product information available at the time of publication. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO TWISTORK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO TWISTORK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.