User manual GRACO SYSTEM HVLP TURBINE REV D 309246
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO SYSTEM HVLP TURBINE. We hope that this GRACO SYSTEM HVLP TURBINE user guide will be useful to you.
Manual abstract: user guide GRACO SYSTEM HVLP TURBINEREV D 309246
Detailed instructions for use are in the User's Guide.
[. . . ] READ AND KEEP FOR REFERENCE.
System HVLP Turbine Sprayers
120V AC 50/60 Hz
System 2500t Sprayer with Two-Stage Turbine Model 826000 5 psi (34 kPa, 0. 3 bar) Maximum Working Pressure System 3800t Sprayer with Three-Stage Turbine Model 826001 6 psi (41 kPa, 0. 4 bar) Maximum Working Pressure System 4900t Sprayer with Four-Stage Turbine Model 826004 8 psi (55 kPa, 0. 5 bar) Maximum Working Pressure
Model descriptions are in Turbine Components Table on page 4.
Related Manuals
System ProCartt . 309205
7947A
System 4900t Shown
The SHERWINWILLIAMS COMPANY, CLEVELAND, OHIO 44115
ECOPYRIGHT 2000, GRACO INC.
Table of Contents
Warnings . 24
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. [. . . ] Clean spray gun and cup as instructed in HVLPTurbine Spray Gun manual 309205.
10
309246
Maintenance
Daily
The System HVLP Turbine Sprayers are lifetime lubricated. The turbine filter must be clean at all times to provide sufficient air flow to cool motor and atomize the fluid. NOTE: To check filter, turn on turbine and place piece of paper against pre-filter. System 3800t and System 4900t models have an air filter indicator light on the front panel. If the filter is clogged or has low airflow the light will come on as in Fig. 7 below.
WARNING
To avoid damage to the turbine and possible electric shock, never install a damp filter in the turbine.
CAUTION
To keep out dirt, do not operate the turbine sprayer without both filters installed.
1 20 21 22 16
Fig. Loosen four thumbscrews (16), and remove filter retainer (15) and pre-filter (22). Remove main filter (21) and clean by using one of the following three methods: D Tap filter gently on flat surface, dirty side down.
8049A
15
03072
Weekly
Check hose for cracks, leaks, and holes. Replace if necessary.
Annually or Every 600 Hours, Whichever Comes First
Replace motor brushes 600 hours after turbine sprayer operation. NOTE: It is recommended that an authorized service center perform the motor brush replacement procedure on page 14.
CAUTION
To prevent damage to filter, do not use compressed air on a wet filter. D Direct compressed air (100 psi [7 bar, 70 kPa] maximum) through filter panel in opposite direction of arrows on side of filter (from the clean side to the dirty side). Do not use compressed air on damp or wet filter.
D
309246
11
Notes
12
309246
Troubleshooting
PROBLEM No fluid delivery CAUSE No material, no remote container pressurization, hose or pickup tube clogged SOLUTION Check container for material.
Check for leaks at the container gasket (2-quart pressure pot cover or 21/2-gallon pressure pot wing nuts). Check for air flow from male quick disconnect at compressor outlet (should be approx. Check hole in 21/2-gallon pressure pot cover under regulator or in 2-quart pressure pot cover at needle valve. Compressor not starting Turbine not starting Cold weather operation See System ProCartt Cold Weather Operation on page 9. Remove cover and turbine, and check for free motor rotation and for brush wear. Return to authorized service center.
No power
Hose too long Circuit breaker trips Filter clogged High ambient temperature Excessive brush wear
Excessive current draw
309246
13
Repair
WARNING
Turn off turbine and unplug power for the following procedures.
Motor Brush Replacement
NOTE: It is recommended that this procedure be performed by an authorized service center. Use System HVLP Turbine Sprayer Disassembly procedure on page 14 to take turbine apart. Note: Do not install new brushes in a turbine that has had brush holders damage the commutator. Keep lead wires from all rotating parts and motor frame.
System HVLP Turbine Sprayer Disassembly
1. If necessary, clean and replace filter according to maintenance procedure on page 11. Carefully lift unit by turbine baseplate (2) from turbine cover (1), and place upright on work surface. [. . . ] 1 phase, 14A minimum Power cord (extension cord must be 3-wire, 12 AWG, 50 ft [15 m] or shorter) System 2500t . aluminum, polyethylene 2-quart (1. 9 liter) accessory remote pressure pot . aluminum, brass, polyethylene 21/2-gallon (9. 5 liter) accessory remote pressure pot . steel with solvent-resistant finish, EPDM gasket (standard) Turbine shipping weight System 2500t . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO SYSTEM HVLP TURBINE
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO SYSTEM HVLP TURBINE will begin.