Detailed instructions for use are in the User's Guide.
[. . . ] Operation
309551H
Electric, Heated, Plural Component Proportioner
For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres.
See Models and Maximum Working Pressures on page 3.
Important Safety Instructions
Read all warnings and instructions in this manual. 42
2
309551H
26
26
Models
E SERIES
Voltage (phase) 230V (1) 230V (1) 380V (3) 380V (3) 230V (3) 230V (3) 230V (1) 230V (3) 380V (3) Heater Watts 6, 000 10, 200 6, 000 10, 200 6, 000 10, 200 15, 300 15, 300 15, 300 Flow lb/min (kg/min) 20 (9) 30 (13. 5) 20 (9) 30 (13. 5) 20 (9) 30 (13. 5) 30 (13. 5) 30 (13. 5) 30 (13. 5) Output per Cycle (A + B) gal. (liter) . 0104 (. 0395) . 0272 (0. 1034) . 0104 (. 0395) . 0272 (0. 1034) . 0104 (. 0395) . 0272 (0. 1034) . 0272 (0. 1034) . 0272 (0. 1034) . 0272 (0. 1034) Maximum Fluid Working Pressure psi (MPa, bar) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140)
Part No. [. . . ] Set transformer wire
taps
WARNING 100 ft 50 ft 150 ft 200 ft 250 ft 300 ft
Read warnings, page 5.
Turn main power switch OFF
. Transformer tap
wire connections vary depending on length of heated hose. Verify that tap wire connections are correct.
50 ft
100 ft
150 ft
TI3470a
200 ft
Hose Length* ft (m) 60-85 (18. 3-25. 9) 110-135 (33. 5-41. 2) 160-185 (48. 8-56. 4) 210-235 (64. 1-71. 7) 260-285 (79. 3-86. 9) 310 (94. 6)
TI3469a
Tap Terminal Label (ft) 50 100 150 200 250 300
* Length includes heated fluid hose and whip hose. Hose Length* ft (m) 60-85 (18. 3-25. 9) 110-135 (33. 5-41. 2) 160-185 (48. 8-56. 4) 210-235 (64. 1-71. 7) Tap Terminal Label (ft) 50 100 150 200
* Length includes heated fluid hose and whip hose. 7: Model E-20 and E-XP1 Transformer Wire Taps
309551H
23
Setup
12. e.
Object being sprayed: follow your local code.
Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.
Read warnings, page 5.
a. See page 17.
Spray gun: connect whip hose ground wire to FTS, page 20. Do not disconnect wire or spray without whip hose.
f.
To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.
c.
Fluid supply containers: follow your local code.
24
309551H
Setup
13. Supply wet-cups with
Throat Seal Liquid
WARNING
b.
Component B (Resin) Pump: Check felt washers in packing nut/wet-cup (R) daily. Replace felt washers when worn or contaminated with hardened material.
Pump rod and connecting rod move during operation. Turn main power OFF before filling wet cup.
R
a.
Component A (ISO) Pump: Keep reservoir (R) filled with Graco Throat Seal Liquid (TSL), Part No. Wet-cup piston circulates TSL through wet-cup, to carry away isocyanate film on displacement rod.
TI3765a-1
R
TI3765a-2
309551H
25
Startup
Startup
WARNING
c.
Turn both PRESSURE RELIEF/SPRAY valves (SA, SB) to SPRAY.
Do not operate Reactor without all covers and shrouds in place.
SA SB
1. Fluid Temperature
Sensor (FTS) Calibration
Calibrate the FTS ONLY at initial startup (the first time the unit is operated) and any time the hose length changes.
TI2482A
d.
Open fluid inlet valves (FV). FV
a.
Before turning on the unit, ensure all hoses and cables are properly connected. To ensure that the FTS in the hose is at the same temperature as the heaters, keep heat off and store the hose FTS near the machine for several minutes.
TI2501A
b. c.
While holding down the temperature unit button (Fahrenheit - "F" or Celsius "C") turn the Reactor main power ON. Hold the temperature unit button until temperature is shown on the display. The fluid temperature sensor is now correctly calibrated.
e.
Start feed pumps.
WARNING
Always provide two grounded waste containers to keep component A and component B fluids separate.
2. Load fluid with feed
pumps
The Reactor is tested with oil at the factory. See page 37.
f.
Hold gun fluid manifold over two grounded waste containers. [. . . ] 246024, 246025, 246026, 246028, 248657: 195-264 Vac, 50/60 Hz Part Nos. 246029, 246030, 246031, 246032, 248659: 338-457 Vac, 50/60 Hz Amperage Requirement Heater Power Part Nos. 246033, 246034, 246035, 246036, 248658: 195-264 Vac, 50/60 Hz See TABLE 1, page 16. Model E-20: 6000 Watts Model E-30 and E-XP1: 10200 Watts Sound Power, per ISO 9614-2 Models E-XP2 and E-30 with 15. 3kW of heat: 15300 Watts Model E-20: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-30: 93. 5 dB(A) at 1000 psi (7 MPa, 70 bar), 3. 0 gpm (11. 4 lpm) Model E-XP1: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-XP2: 83. 5 dB(A) at 3000 psi (21 MPa, 210 bar), 1. 0 gpm (3. 8 lpm) Sound Pressure, 1 m from equipment Model E-20: 70. 2 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-30: 83. 6 dB(A) at 1000 psi (7 MPa, 70 bar), 3. 0 gpm (11. 4 lpm) Model E-XP1: 70. 2 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Fluid Inlets Fluid Outlets Fluid Circulation Ports Weight Model E-XP2: 73. 6 dB(A) at 3000 psi (21 MPa, 210 bar), 1. 0 gpm (3. 8 lpm) 3/4 npt(f), with 3/4 npsm(f) union Component A (ISO): #8 JIC (3/4-16 unf), with #5 JIC adapter Component B (RES): #10 JIC (7/8-14 unf), with #6 JIC adapter 1/4 npsm(m), with plastic tubing Model E-20 and E-XP1: 342 lb (155 kg) Model E-30: 400 lb (181 kg) Wetted Parts Models E-XP2 and E-30 with 15. 3kW of heat: 438 lb (198 kg) Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
309551H
41
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. [. . . ]