Detailed instructions for use are in the User's Guide.
[. . . ] Setup, Operation, Service, and Repair
TM ProControl
311190D
ENG
For flow control of mixed, catalyst, and resin coatings. Models with G250, G250HR, or no meters are approved for use in explosive atmospheres. See page 4.
Important Safety Instructions
Read all warnings and instructions in this manual. 52
2
311190D
Related Manuals
Related Manuals
Component Manuals in English
Manual 311090 310655 308778 310696 311191
Description ProControlTM Setup, Operation, Service, and Repair Dispense Valve Volumetric Fluid Flow Meter Coriolis Flow Meter ProMix AutoTM & ProControlTM Network Communications
This manual (311190) is available in the following languages:
Manual 311190 311267 311268 311269 311270
Language English French Spanish German Japanese
Manual 311271 311272 311295 311294
Language Chinese Korean Italian Dutch
311190D
3
ProControlTM Models
ProControlTM Models
Do not install equipment approved only for a non-hazardous location in a hazardous area. [. . . ] 13 Automatic Run Display Screen Status Bar (A) - displays Active, Standby or Alarm/Warning. Operating Status (B) - displays mode (manual, auto).
NOTE:
At very low flow rates such as 20 - 50 cc/min 1/8" tubing or smaller and 0. 33 or smaller gun setup will be required depending on viscosity. · To determine the correct setup use an air pressure gauge and fluid pressure gauge to confirm proper back pressure.
Test the system at the lowest flow rate set point to ensure minimum pressures are met. Unnecessary warnings and alarms may occur if pressure are lower than the 7 psi (0. 48 bar) allowed. The flow rate warning on the status bar indicates the flow rate through the meter has fallen below or gone above the flow tolerance.
311190D
21
Operation and System Setup
EasyKey Display
LCD Display Keypad
AC Power Switch
Navigation Keys
Alarm Reset Key Discrete I/O Cable Connector Port
Fiber Optic Strain Relief Port
Audible Alarm
I/S Power
Graco Web Interface
Mod/bus TCP I/O Interface Port
FIG. 14
AC Power Switch - Turns system AC power on or
off.
Pressing any key brings the display out of screen saver mode.
Keypad - Used to input numerical data, enter setup
screens, scroll through screens manual operation, and select setup values. See page 23 for additional keypad/screen navigation information.
Audible Alarm - Provided to alert the user when an alarm condition occurs. The alarm is cleared by pressing the EasyKey
Display Error Clear key. See Alarm Troubleshooting on page 35 for more information.
I/S Power - Power circuit to Smart Meter Panel. Backlit LCD Display - Shows graphical and text information related to setup and flow operation. The back light on the screen will turn off after 10 minutes.
22
311190D
Operation and System Setup
Key Commands
In addition to the numbered keys on the EasyKey keypad, which are used to enter values in setup, there are the following keys to navigate within a screen and between screens, and to save entered values.
Ethernet Connection
You can access data from the ProControl on an office or industrial network or through the internet with the proper network configuration.
Key
Function
Setup: press to enter or exit Setup mode. Enter: if cursor is in drop-down list box, press Enter key to view drop-down list. Press Enter to save a value either keyed in from the numerical keypad or selected from a drop-down list. Alarm Reset
Graco PC Cable Port
The Graco PC Cable Port is for use with the ProControl Web Interface which enables you to communicate with the ProControl from a PC to: Upgrade software View software version Download · · · job and alarm logs material usage report setup values (can also upload)
Clear job, alarm, and material usage reports Upload a custom language to view on screen Restore factory defaults Restore setup password See WEB Interface Software manual 311191 for more information.
311190D
23
EasyKey Display Screens
EasyKey Display Screens
Power Up Screens
When the EasyKey power switch is turned on, the Graco logo screen and current software version screen display for several seconds before the run screen appears in the standby mode. The Run screen displays either the manual run screen or the automatic run screen according to the setup being used at the time the power was shut down. 16.
Key
1 Flow Control Tolerance - when flow control is
operating. Designates target material flow designated by robot controller.
3 Animation: When there is flow, the gun appears to
spray.
4 Status Bar: shows current alarm or operation mode
(Run, Standby). 5 Current Date and Time 6 Security Level: a padlock appears on the screen if a password is required to enter Setup mode. If the password was set to "0", no padlock appears and setup can be entered without a password. The only key that functions with the Automatic Run Screen is the Setup key (used to enter Setup .
Automatic Run Mode
Is used when a varying gun flow is needed such as a robot application where an analog 0 - 10 VDC signal is provided to vary the flow being applied. Automatic Run Screen This screen displays the operating status of the system and is the default screen after powering up. 15 Automatic Run Screen
24
311190D
EasyKey Display Screens
Manual Run Mode
Is used when a constant gun flow is needed such as a reciprocating (back and forth) application and when no analog signal is available for a flow control command. [. . . ] below 70 dBA below 85 dBA 303, 304 SST, 174 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE; CV75 31 lbs (14. 1 kg) 22. 2 lbs (10. 0 kg) 6 lbs (2. 8 kg) 4 lbs (1. 8 kg) 2. 6 lbs (1. 8 kg) each 33 lbs (15 kg) each
Viscosity range of fluid Fluid filtration Fluid flow rate range* G250 Meter G250HR Meter Coriolis Meter External Power Supply Requirements
Operating temperature range Environmental Conditions Rating Noise Level Sound pressure level Sound power level Wetted parts Weight Base System EasyKey Display . The ProControl maximum allowable flow meter pulse frequency is 425 Hz (pulses/sec. ). For more detailed information on viscosities, flow rates, or mixing ratios, consult your Graco distributor.
See individual component manuals for additional technical data.
311190D
51
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. [. . . ]