Detailed instructions for use are in the User's Guide.
[. . . ] Installation
E-Flo® Electric Circulation Pump
Approved for use in explosive atmospheres.
See page 3 for model information, including maximum working pressure and approvals.
311592J
ENG
Durable, energy efficient piston pumps for high volume paint circulation applications. For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
E-Flo 4000 Pump Shown
ti8317a
Related Manuals
Contents
Related Manuals . 11 Hazardous Area Cabling and Conduit Requirements (Explosion Proof) . [. . . ] The Secure Disable switch on the Local Control Box Accessory provides this function. See page 18.
·
·
15H884 Floor Stand
1
Use 120351 Gaskets at these locations.
Floor Stand 15H884 is available as an option. See 406638 for assembly and mounting instructions.
R
CG MF
1
SC
ti8744a
FIG. Fluid Connection (Pump Inlet, E-Flo 4000 Shown)
12
311592J
Electric Motor
Electric Motor
Motor Wiring
See the System Wiring Schematics on pages 8 and 9. Improper wiring may cause electric shock or other serious injury if work is not performed properly. Be sure your installation complies with all National, State and Local safety and fire codes. Install an explosion-proof seal fitting in the wall separating the hazardous area from the non-hazardous area. Use explosion-proof conduit or increased safety protection concepts to run wires between the motor junction box and the variable frequency drive (VFD). Use 14 gauge wire (3 wires plus ground) to connect the VFD and the motor. Use 18 gauge wire between pins 8 and 11 on the VFD and the motor overtemperature switch. Motor must be wired to rotate fan counter-clockwise when viewed from fan end of motor. 7.
Electric Motor Specifications
The electric motor must be approved as explosion-proof for use in a hazardous area. All wiring must meet Local and National electric codes for hazardous area. See TABLE 5 on page 14.
Graco does not support the use of the Graco VFD CAM mode on motors not supplied by Graco. 255226 255225 289552 289551 Voltage 230/400V 230/460V 230/400V 230/460V Phase 3 3 3 3 Supply Frequency 50 Hz 60 Hz 50 Hz 60 Hz Horsepower 5 5 3 3 rpm 1500 (4 pole) 1800 (4 pole) 1500 (4 pole) 1800 (4 pole) Full Load Torque 15 ft-lb (20. 3 N·m) 15 ft-lb (20. 3 N·m) 9. 1 ft-lb (12. 3 N·m) 9. 1 ft-lb (12. 3 N·m)
311592J
13
Electric Motor
Install the Motor
15
Apply antiseize lubricant to bore of coupling (28).
A NEMA 182/184 TC Frame is required to mate with the gear reducer. If the pump is purchased without a motor, you must order a kit to mate with the gear reducer. 16C487 Description
20 28
105
Coupler Kit for NEMA 182-184 TC Frame 3 or 5 HP motors. 24E453 Mounts IEC 112M/B5 or 100L/B5 Frame 3 or 5 HP motor to gear reducer. Measure the length of the motor keyway to determine the correct key length. Key length should be at least 90% of keyway length.
15
ti8913a
FIG. Slide the coupler into the gear reducer so the key and input shaft mate with the coupler. Apply antiseize lubricant to bore of coupling.
When installing an IEC 112M/B5 or 100L/B5 Frame electric motor, ensure that the motor adapter (MA) and screws (MS) are in place before mounting the motor on the gear reducer. [. . . ] E-Flo 1500: 425 psi (2. 93 MPa, 29. 3 bar) E-Flo 2000: 460 psi (3. 22 MPa, 32. 2 bar) E-Flo 3000: 330 psi (2. 31 MPa, 23. 1 bar) E-Flo 4000: 250 psi (1. 75 MPa, 17. 5 bar) European Models: 230/400 Vac, 3 phase, 20 A/15 A North American Models: 230/460 Vac, 3 phase, 20 A/15 A 32-104°F (0-40°C) See charts on page 23. 288414) Pump: 550 lb (249 kg) Lower: see manual 311690 300 Series SST, CV-75, 17-4 PH SST, PTFE E-Flo 1500: 3 HP, 1800 rpm (60 Hz) or 1500 rpm (50 Hz), NEMA 182 TC Frame E-Flo 2000/3000/4000: 5 HP, 1800 rpm (60 Hz) or 1500 rpm (50 Hz), NEMA 184 TC Frame 1500 rpm (50 Hz) 1800 rpm (60 Hz) E-Flo 1500: 9. 1 ft-lb (12. 3 N·m) E-Flo 2000/3000/4000: 15 ft-lb (20. 3 N·m) 75. 16:1
Electrical Requirements . .
22
311592J
Technical Data
psi (MPa, bar) 500 (3. 50, 35. 0) 450 (3. 15, 31. 5)
Pressure and Flow Capability of E-Flo Family with 50 Hz Motor (continuous production use) Key: A B C
A B C D E-Flo 1500 E-Flo 2000 E-Flo 3000 E-Flo 4000
400 (2. 80, 28. 0) 350 (2. 41, 24. 1)
D
Fluid Pressure
300 (2. 10, 21. 0) 250 (1. 72, 17. 2) 200 (1. 4, 14. 0) 150 (1. 03, 10. 3) 100 (0. 70, 7. 0) 50 (0. 35, 3. 5) 0 5 (19) 10 (38) 15 (57) 20 (76) 25 (95)
Fluid Flow in gpm (lpm)
psi (MPa, bar) 500 (3. 50, 35. 0) 450 (3. 15, 31. 5) 400 (2. 80, 28. 0) 350 (2. 41, 24. 1)
Pressure and Flow Capability of E-Flo Family with 60 Hz Motor (continuous production use) Key: A B C D
A B C D E-Flo 1500 E-Flo 2000 E-Flo 3000 E-Flo 4000
Fluid Pressure
300 (2. 10, 21. 0) 250 (1. 72, 17. 2) 200 (1. 4, 14. 0) 150 (1. 03, 10. 3) 100 (0. 70, 7. 0) 50 (0. 35, 3. 5) 0 5 (19) 10 (38) 15 (57) 20 (76) 25 (95) 30 (114)
Fluid Flow in gpm (lpm)
311592J
23
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. [. . . ]