Detailed instructions for use are in the User's Guide.
[. . . ] Instructions
Manual Electrostatic
PROTM Xs Waterborne Air Spray Gun
For use with conductive spray materials (waterborne and other materials less than 1 megohm-cm). I hazardous locations using Group D spray materials.
312900D
ENG
For use in Group II, Zone 1 areas using Group IIA spray materials.
II 2 G EEx 0. 24 mJ
247936 Standard Model 247937 Smart Model
100 psi (0. 7 MPa, 7 bar) Maximum Air Inlet Pressure 100 psi (0. 7 MPa, 7 bar) Maximum Working Fluid Pressure
Important Safety Instructions:
Read all warnings and instructions in this manual. Patent Pending
Smart Model 247937
Standard Model 247936
Table of Contents
Warnings . 44
2
312900D
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. [. . . ] Do not install or repair this equipment unless you are trained and qualified.
Problem Cause Solution
Poor wrap.
ES ON/OFF valve OFF (0). *
Turn ON (I). Check air pressure to gun; minimum 40 psi (0. 28 MPa, 2. 8 bar) needed at gun for full voltage. See Check Electrical Grounding on page 15 and Test Total Gun Resistance on page 23. Clean workpiece hangers.
(In general, a Pro Xs Waterborne gun Gun air pressure too low. will have less wrap than a Pro Xs solventborne gun. ) Atomizing air pressure too high. Workpiece not grounded.
* ES indicator light is off when the gun is triggered.
22
312900D
Electrical Tests
Electrical Tests
Electrical components inside the gun affect performance and safety. The following procedures test the condition of the power supply (18), barrel (16) and charging probe (31), and electrical continuity between components. Connect the leads as shown.
Test Gun Resistance
Measure resistance between the air swivel (35) and the charging probe socket (CC) (see FIG. If in range, test the charging probe resistance.
AA
Fire, Explosion, and Electric Shock Hazard Megohmmeter Part No. To reduce the risk of sparking, do not use the megohmmeter to check electrical grounding unless: · The gun has been removed from the hazardous area; or · all spraying devices in the hazardous area are turned off, ventilation fans in the hazardous area are operating, and there are no flammable vapors in the area (such as open solvent containers or fumes from spraying). Failure to follow this warning could cause fire, explosion, and electric shock and result in serious injury and property damage.
35
CC
ti13731
FIG. Test Gun Resistance
Test Charging Probe Resistance
Measure resistance between the metal spring in the charging probe (DD) and the charging probe tip (BB) (see FIG. If in range, inspect the spring and barrel socket for possible causes of poor continuity. Reassemble the charging probe and retest the gun resistance.
Test Total Gun Resistance
Measure resistance between the charging probe tip (BB) and the air swivel (35) (see FIG. If in range, refer to Gun Repair on page 27 for other possible causes of poor performance.
AA
AA BB BB DD
ti13732
FIG. Test Total Gun Resistance
312900D
23
Electrical Tests
Test Power Supply Resistance
1. Measure resistance from the power supply's ground strips (EE) to the conductive contact in the center of the power supply seal (FF). Insert a conductive rod (GG) into the gun barrel (removed for the power supply test) and against the metal contact (HH) in the front of the barrel. Measure the resistance between the conductive rod (GG) and the charging probe socket (CC). If resistance is in range, reassemble the gun and test the gun resistance. If you still have problems, refer to Gun Repair on page 27 for other possible causes of poor performance, or contact your Graco distributor.
AA
AA
FF
EE
ti1599a
Fig. Test Barrel Resistance
24
312900D
Spray Pattern Troubleshooting
Spray Pattern Troubleshooting
Electric Shock Hazard Installing and servicing this equipment requires access to parts which may cause an electric shock or other serious injury if the work is not performed properly. [. . . ] Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data 100 psi (0. 7 MPa, 7 bar) 100 psi (0. 7 MPa, 7 bar) 120°F (49°C) 60kV at 40 psi (0. 28 MPa, 2. 8 bar); 90. 4 dB(A) at 100 psi (0. 7 MPa 7 bar): 105. 4 dB(A) at 40 psi (0. 28 MPa, 2. 8 bar); 87 dB(A) at 100 psi (0. 7 MPa 7 bar): 199 dB(A) 1/4 npsm 3/8-18 npsm (R 3/8-19) compound thread 247936: 22. 4 oz (634 g) 247937: 25. 1 oz (712 g) 10. 6 in. (24. 6 cm) <1 megohm-cm Polyethylene, Stainless Steel; Nylon, Acetal, PTFE, UHMWPE, Fluoroelastomer, PEEK, Nickel Plate
312900D
43
Graco Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months or two thousand hours of operation from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. [. . . ]