User manual GRACO 15V534 GUN FLUSH INSTRUCTIONS PARTS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO 15V534 GUN FLUSH. We hope that this GRACO 15V534 GUN FLUSH user guide will be useful to you.


GRACO 15V534 GUN FLUSH INSTRUCTIONS PARTS: Download the complete user guide (1268 Ko)

Manual abstract: user guide GRACO 15V534 GUN FLUSHINSTRUCTIONS PARTS

Detailed instructions for use are in the User's Guide.

[. . . ] GFB Interface Module Identification Label 2 313212A Installation Installation Location Install the gun flush box module enclosure (1) within 15 ft (4. 5 m) of the RoboMix, to ensure that the cable (23) will reach the RoboMix. Turn off equipment power and shut off power at main circuit breaker before installing. All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. Do not substitute system components as this may impair intrinsic safety. · Mount the Enclosure 1. [. . . ] Connect the wires from PS#1 to the right side of the terminal strip (12) pins 5 (+) & 6 (-), as indicated by the label (21). 12 21 Pressure switch is part of gun flush box kit; not included with GFB Interface Kit. 1 PS#1 TI14279a FIG. If using a second gun flush box, connect the wires from PS#2 to the right side of the terminal strip (12) pins 7 (+) & 8 (-), as indicated by the label (21). Install Pressure Switch (two shown) 6 313212A Installation Install the Solenoid NOTE: The GFB Interface Module Kit does not include a solenoid (SO). Install the solenoid(s) on the manifold at the bottom rear of the enclosure. If you are using two gun flush boxes, remove the two sealing screws (4) from the solenoid manifold (8) before installing SO#2. Connect the wires from SO#1 to the right side of the terminal strip (12), as indicated by the label (21); red (+12V) to pin 9, black (COM) to pin 10. 12 21 Solenoid is part of gun flush box kit; not included with GFB Interface Kit. TI14279a FIG. If using a second gun flush box, connect the wires from SO#2 to the right side of the terminal strip (12), as indicated by the label (21); red (+12V) to pin 11, black (COM) to pin 12. Install Solenoid (two shown) 313212A 7 Installation Connect the Cable to the RoboMix Control Board NOTICE To avoid damaging circuit board when servicing, wear grounding strap on wrist and ground appropriately. 10: RoboMix Control Board J8 Connections 8 313212A Installation Connect the Gun Flush Box NOTE: Use 5/32 in. (4 mm) OD tubing to connect the gun flush box air ports to the interface module air ports, as follows. See the gun flush box manual for details on the safety shutoff valve. Replace the Cover Reinstall the cover on the enclosure and secure with the four captive screws. Ground the Enclosure Connect a ground wire (Y) from the enclosure's ground screw (6) to a true earth ground. 11. Y 6 TI14277a Connect Air Supply to Module Connect a 1/4 in. (6 mm) OD tube between a clean, dry air supply (filtered to 10 microns) and the module air inlet fitting (13). Ground the Enclosure GUN FLUSH BOX P A P A C S INTERFACE MODULE C S AFS AIR SAFETY SHUTOFF VALVE IN C TI13110b P TI14278a FIG. 12: Gun Flush Box to Interface Module Air Connections 313212A 9 Installation 10 313212A Parts Parts 1 9 6 16 10 11 12 TI14279a 20 21 7 3 18 13 14 8 1 (Ref) 15 1 1 If using two gun flush boxes, remove item 5 and two of item 4. TI14280a 5 4 1 12 (Ref) 23 24 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 AIR FLOW SWITCH #1 + (BLK) AIR FLOW SWITCH #1 - (WHT) AIR FLOW SWITCH #2 + (RED) AIR FLOW SWITCH #2 - (GRN) PRESSURE SWITCH #1 + (ORG) PRESSURE SWITCH #1 - (BLU) PRESSURE SWITCH #2 + (WHT/BLK) PRESSURE SWITCH #2 - (RED/BLK) SOLENOID #1 +12 (GRN/BLK) SOLENOID #1 COM (ORG/BLK) SOLENOID #2 +12 (BLU/BLK) SOLENOID #2 COM (RED/WHT) Cable (23) Wire Harness Detail 25 Ref. Description 15V531 118435 121628 113279 116343 114421 15V533 116457 116804 116459 116458 ENCLOSURE, GFB module GROMMET SCREW, self-sealing PLUG, fitting, tube SCREW, ground BUSHING, strain relief MANIFOLD, GFB solenoid RAIL; 3 in. (76 mm) BLOCK, end, terminal COVER, end, terminal TERMINAL, rail mount Qty 1 1 4 1 1 1 1 1 2 2 12 Ref. OD 2 113045 SCREW, machine, truss-hd 2 103832 SCREW, machine 1 n/a TUBE, nylon; 1. 2 in. [. . . ] GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc. ), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO 15V534 GUN FLUSH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO 15V534 GUN FLUSH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.