User manual FLUSHMATE 504

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUSHMATE 504. We hope that this FLUSHMATE 504 user guide will be useful to you.


FLUSHMATE 504 : Download the complete user guide (58 Ko)

Manual abstract: user guide FLUSHMATE 504

Detailed instructions for use are in the User's Guide.

[. . . ] NEVER use corrosive disinfectants, bowl cleaners or deoderant blocks on FLUSHMATE products. INSTALLATION ____________________________________________________________________________________ The Sloan FLUSHMATE ® Flushometer -Tank System Fixture installs in the same manner as other water closets. Using the gasket, washer and nuts provided with the fixture, assemble the tank to the bowl. Before connecting the supply to the tank, be sure the supply line is flushed clean. [. . . ] If the water stops running, it is an indication that the Flush Valve Cartridge requires tightening (clockwise). If water still runs on while pushing down on the actuator, the Flush Valve Cartridge requires loosening (counter-clockwise). NOTE: Adjust the Flush Valve Cartridge Assembly in quarter to half turn increments until the water stops running. If replacement of the Flush Valve Cartridge is necessary, follow the instructions in Step 5. If OK, then check the Flush System by removing the tank Cover and tripping the Actuator. Water should flow freely and wash away any debris in the supply line and Vessel. To test the Air Inducer, place a small amount of water (2 to 3 drops) in the orifice of the Air Inducer cap and flush the toilet. If the Air Inducer is functioning properly the water will be drawn in. If not, it will need to be cleaned and tested again. FIGURE 3 Air Inducer Cap TO CLEAN AIR INDUCER: (Figures 3 & 4) a) Turn off the water supply and trip the Actuator. b) Unscrew the Air Inducer Cap, clean thoroughly and remove any obstructions. Wait for the Vessel to refill (30 to 60 seconds. ) Repeat Step 2 above. If the Air Inducer does not function properly, replace the Upper Supply Assembly. Turn the water supply off and drain the vessel by tripping the Actuator and holding it down until completely drained. Next, pour a cup of water onto the Cartridge Housing area as shown in Figure 5. If a leak is detected (a steady flow of bubbles from the center of the Cartridge Area), the Cartridge should be replaced. Turn the water off and relieve the Vessel pressure by flushing the toilet. Reattach the supply line to the supply shank and observe connections to assure no leakage. IMPORTANT: If you are still experiencing a weak or sluggish flush after this point, it is recommended you replace the entire Lower Supply group. proper drain ventilation Consult a professional for recommendations if any of these conditions exist. If the drain and drain vent are clear, and the flush has not been improved, replace the Lower Supply Assembly. FIGURE 4 FIGURE 5 TROUBLESHOOTING___________________________________________________________________________________ CONDITION: No Flush Step 1. Review all of Step 3 and Step 4 covered in "Weak or Sluggish Flush" Condition. NEVER use lubricant on the "O" Ring (Arrow - Figure 6). FIGURE 6 CONDITION: Relief Valve Discharging This is a sign that the Lower Supply Group (Number 1 from list of components) is not working properly and should be replaced. [. . . ] Bowl Procedure: After flushing out the Vessel, remove the remaining water from the bowl or add from 1 pint to 1 quart of antifreeze or RV antifreeze to the water remaining in the bowl. NOTE: Refer to fixture manufacturer's instructions for procedures to winterize bowl. POINTS TO REMEMBER _____________________________________________________________________________ Safety Notice · When servicing any component, the water supply should be turned OFF and the Actuator tripped to relieve the pressure in the Vessel. · The Flush Valve Cartridge Assembly can be removed by inserting the handles of a pair of pliers into the top of the Cartridge and turning counter-clockwise. · NEVER use any corrosive disinfectants, bowl cleaners or deoderant blocks on FLUSHMATE ® products or in the china tank. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUSHMATE 504




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUSHMATE 504 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.