User manual FLUSHMATE 501

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUSHMATE 501. We hope that this FLUSHMATE 501 user guide will be useful to you.


FLUSHMATE 501 : Download the complete user guide (763 Ko)

Manual abstract: user guide FLUSHMATE 501

Detailed instructions for use are in the User's Guide.

[. . . ] Do this by running water from the supply stop into a bucket until water flows clear. After connecting the supply line to the tank, turn on the water again and check for leaks. You may be required to make adjustments to the actuator for either pushbutton type or trip lever type units. Please follow the instructions provided by the fixture manufacturer. TROUBLESHOOTING _____________________________________________________________ CONDITION: Water runs on and will not shut off. [. . . ] b) Remove the Flush Valve Cartridge Assembly using pliers' handles as shown in Figure 2. NOTE: You may be required to disconnect the Actuator Linkage Rod to remove the Flush Valve Cartridge Assembly. c) Inspect the "O" Rings on the Flush Valve Cartridge and the seating area inside the tank for wear and/or improper seating. First, insert the cartridge into vessel and, while gently pushing down on the Cartridge, turn the Cartridge counterclockwise until you hear an audible click, indicating that the threads are now aligned. Screw Cartridge clockwise into place until two black threads of the Vessel are showing. Next, turn on the water and continue to turn cartridge until the water stops running. If the Tank continues to run on, push down lightly on the Flush Valve Actuator. If the water stops running, it is an indication that the Flush Valve Cartridge requires tightening (clockwise). If water still runs on while pushing down on the Actuator, the Flush Valve Cartridge requires loosening (counter-clockwise). NOTE: Adjust the Flush Valve Cartridge Assembly in quarter- to half-turn increments until the water stops running. If replacement of the Flush Valve Cartridge is necessary, follow the instructions in Step 5. TROUBLESHOOTING _____________________________________________________________ CONDITION: Weak or Sluggish Flush. Unscrew the plastic nut that holds the vessel to the bottom of the China Tank and carefully remove the entire vessel from the China Tank. WHEN REMOVING OR REPLACING THE LOWER SUPPLY, DO NOT WIGGLE THE LOWER SUPPLY FROM SIDE TO SIDE AS YOU MAY BREAK THE POST THAT THE LOWER SUPPLY SLIDES ONTO. THIS IS A PRESS FIT AND ONLY MINIMUM DOWNWARD OR UPWARD FORCE IS REQUIRED. Cut the hose just above the barbed fitting (about (1/4" above clamp) on the Lower Supply. Reassemble vessel to China Tank, tighten securely, reconnect water supply and check for leaks. WINTERIZING___________________________________________________________________ The Sloan FLUSHMATE ®, when installed in a summer home, cottage or cabin, can be winterized to allow for periods for nonuse especially when the dwelling is subject to frigid conditions. Turn off the water supply line valve and remove the Toilet Tank Cover. Push the Actuator on top of the Vessel to flush and discharge the water. Disconnect the supply line coupling nut from the Lower Supply located under the Toilet Tank Housing. Remove the Supply Shank and drain the water from the bottom of the china tank into a bucket. Push down on the Actuator one more time, then pull it up momentarily to allow air into the Vessel. Bowl Procedure: After flushing out the Vessel, remove the remaining water from the bowl or add from 1 pint to 1 quart of antifreeze or RV antifreeze to the water remaining in the bowl. [. . . ] However, if servicing is ever required, it is recommended that you follow the instructions included in this brochure. If you would like additional information or require technical assistance, write or call us at the address or telephone number below. ATTENTION OWNER THIS IS YOUR WARRANTY REGISTRATION Sloan FLUSHMATE (the "Company") warrants the FLUSHMATE® flushometer tank operating system (the "unit") to be free of defects in material and workmanship for a period of two (2) years from the date of installation and the Company promises to replace any part of this product that proves, upon our inspection and within two (2) years from date of installation, to be defective in material or workmanship. All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser-user. This warranty is subject to the following: Specific Conditions to Warranty A Warranty Registration card has been fully completed and mailed by the purchaser (the "user") to the Company within thirty (30) days of the date of installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUSHMATE 501




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUSHMATE 501 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.