User manual FLUKE 80 V

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE 80 V. We hope that this FLUKE 80 V user guide will be useful to you.


FLUKE 80 V : Download the complete user guide (1175 Ko)

Manual abstract: user guide FLUKE 80 V

Detailed instructions for use are in the User's Guide.

[. . . ] 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www. TestEquipmentDepot. com ® 80 Series V Multimeters Users Manual May 2004 Rev. All product names are trademarks of their respective companies. Table of Contents Title Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacting Fluke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Testing for Continuity 17 80 Series V Users Manual Measuring Resistance WCaution To avoid possible damage to the Meter or to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before measuring resistance. The Meter measures resistance by sending a small current through the circuit. Because this current flows through all possible paths between the probes, the resistance reading represents the total resistance of all paths between the probes. The Meter's resistance ranges are 600. 0 , 6. 000 k, 60. 00 k, 600. 0 k, 6. 000 M, and 50. 00M. To measure resistance, set up the Meter as shown in Figure 5. The following are some tips for measuring resistance: · · The measured value of a resistor in a circuit is often different from the resistor's rated value. The test leads can add 0. 1 to 0. 2 of error to resistance measurements. To test the leads, touch the probe tips together and read the resistance of the leads. If necessary, you can use the relative (REL) mode to automatically subtract this value. The resistance function can produce enough voltage to forward-bias silicon diode or transistor junctions, causing them to conduct. If this is suspected, press C to apply a lower current in the next higher range. Refer to Table 18. · 18 Making Measurements In-Circuit Resistance Measurements Circuit Power 87 V TRUE RMS MULTIMETER Isolating a Potentiometer OFF 1 32 Disconnect °C/°F MIN MAX Peak MIN MAX REL Hz % RANGE AutoHOLD 4½ DIGITS 1 Second mV V mA A 1 3 A 2 LO V OFF Isolating a Resistor mA A COM V A 10A MAX FUSED 400mA FUSED Disconnect aom6f. eps Figure 5. Measuring Resistance 19 80 Series V Users Manual Using Conductance for High Resistance or Leakage Tests Conductance, the inverse of resistance, is the ability of a circuit to pass current. The Meter's 60 nS range measures conductance in nanosiemens (1 nS = 0. 000000001 Siemens). Because such small amounts of conductance correspond to extremely high resistance, the nS range lets you determine the resistance of components up to 100, 000 M, 1/1 nS = 1, 000 M. To measure conductance, set up the Meter as shown for measuring resistance (Figure 5); then press Cuntil the nS indicator appears on the display. The following are some tips for measuring conductance: · High-resistance readings are susceptible to electrical noise. To smooth out most noisy readings, enter the MIN MAX recording mode; then step to the average (AVG) reading. There is normally a residual conductance reading with the test leads open. To ensure accurate readings, use the relative (REL) mode to subtract the residual value. · 20 Making Measurements Measuring Capacitance WCaution To avoid possible damage to the Meter or to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance. Use the dc voltage function to confirm that the capacitor is discharged. The Meter's capacitance ranges are 10. 00 nF, 100. 0 nF, 1. 000 µF, 10. 00 µF, 100. 0 µF, and 9999 µF. To improve the accuracy of measurements less than 1000 nF, use the relative (REL) mode to subtract the residual capacitance of the Meter and leads. Select Capacitance 4½ DIGITS 1 Second 87 V TRUE RMS MULTIMETER °C/°F MIN MAX Peak MIN MAX REL Hz % RANGE AutoHOLD mV V mA A LO V OFF A A mA A COM V 10A MAX FUSED 400mA FUSED Note If too much electrical charge is present on the capacitor being tested, the display shows "diSC". + + + + + + + + + aom10f. eps Figure 6. Measuring Capacitance 21 80 Series V Users Manual Testing Diodes WCaution To avoid possible damage to the Meter or to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before testing diodes. [. . . ] Specification increases from -1% at 200 Hz to -6% at 440 Hz when filter is in use. 44 Specifications Table 11. Model 83 AC Voltage Function Specifications Function Range Resolution 50 Hz - 60 Hz ± (0. 5 % + 4) ± (0. 5 % + 2) ± (0. 5 % + 2) ± (0. 5 % + 2) ± (0. 5 % + 2) Accuracy 30 Hz - 1 kHz ± (1. 0 % + 4) ± (1. 0 % + 4) ± (1. 0 % + 4) ± (1. 0 % + 4) ± (1. 0 % + 4) 1 kHz - 5 kHz ± (2. 0 % + 4) ± (2. 0 % + 4) ± (2. 0 % + 4) ± (2. 0 % + 4)2 unspecified K 1 600. 0 mV 6. 000 V 60. 00 V 600. 0 V 1000 V 0. 1 mV 0. 001 V 0. 01 V 0. 1 V 1V 1. Frequency range: 1 kHz to 2. 5 kHz. 45 80 Series V Users Manual Table 12. DC Voltage, Resistance, and Conductance Function Specifications Accuracy Function Range 6. 000 V 60. 00 V 600. 0 V 1000 V 600. 0 mV 600. 0 6. 000 k 60. 00 k 600. 0 k 6. 000 M 50. 00 M 60. 00 nS Resolution Model 83 Model 87 ± (0. 05 % + 1) ± (0. 05 % + 1) ± (0. 05 % + 1) ± (0. 05 % + 1) ± (0. 1 % + 1) ± (0. 2 % + 2)1 ± (0. 2 % + 1) ± (0. 2 % + 1) ± (0. 6 % + 1) ± (0. 6 % + 1) ± (1. 0 % + 3)2 ± (1. 0 % + 10)1 0. 001 V 0. 01 V 0. 1 V 1V 0. 1 mV 0. 1 0. 001 k 0. 01 k 0. 1 k 0. 001 M 0. 01 M 0. 01 nS ± (0. 1 % + 1) ± (0. 1 % + 1) ± (0. 1 % + 1) ± (0. 1 % + 1) ± (0. 3 % + 1) ± (0. 4 % + 2)1 ± (0. 4 % + 1) ± (0. 4 % + 1) ± (0. 7 % + 1) ± (0. 7 % + 1) ± (1. 0 % + 3)2 ± (1. 0 % + 10)1 L F mV e nS 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE 80 V




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE 80 V will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.