User manual ESPRIT 728 PLUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ESPRIT 728 PLUS. We hope that this ESPRIT 728 PLUS user guide will be useful to you.


ESPRIT 728 PLUS : Download the complete user guide (1153 Ko)

Manual abstract: user guide ESPRIT 728 PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] The enhanced control panel offers to you the same great features you have come to depend on with added reliability, improved lightning protection and a new innovative dialer circuit. You have selected a sophisticated, user-friendly control panel designed to meet all of your technological, performance and security requirements. 1. 1 About This Manual This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel features and programming. Please refer to the index for a complete list of this manual's contents. [. . . ] All other zone definitions and options do not come into effect until the zone speed has elapsed. Example: The system is armed and the zone speed is set for 1. 2 seconds. A zone opens and closes in less than 1. 2 seconds the control panel will not respond (i. e. This feature prevents any momentary glitches in the system from causing an alarm or unnecessary reporting. [ENTER] + Installer Code + [10] [5] [3] + 3 digit decimal value (001-255) + [ENTER] Zone Speed 7. 2 Feature Select Programming è Address 090, key [8] Default: ATZ Disabled Enabling the ATZ feature allows you to install two detection devices per zone input. Each detection device will have its own zone number and each will transmit a separate alarm code that will display on the keypad. For information on how to connect the detection devices and how the panel recognizes them, please refer to section 2. 10. Key [8] "Off": ATZ Disabled Key [8] "On": ATZ Enabled [ENTER] + Installer Code + [10] [9] [10] + [8] On/Off + [ENTER] Advanced Technology Zoning (ATZ) 7. 3 Feature Select Programming è Address 092, keys [1] to [10] If an alarm condition occurs on a zone identified as Intellizone, the control panel will trigger a timer and will not generate an alarm until one of the following conditions occurs within a specified period (see Intellizone Time Delay below): u An alarm condition occurs on another zone during intellizone time delay. u The zone that is in alarm has restored and re-occurred during intellizone time delay. u The zone that is in alarm remains in alarm the entire intellizone time delay. Note: Intellizone timer will only begin after the zone speed period has elapsed (see section 7. 1). Do not use the Intellizone feature on zones programmed with any Entry Delay!7. 3. 1 Intellizone Time Delay Decimal Programming è Address 057 Default: 48 seconds You can set the Intellizone Time Delay between 010 and 255 seconds. Before an Intellizone can generate an alarm, one of three conditions must occur during this time delay (see section 7. 3). [ENTER] + Installer Code + [10] [5] [7] + 3-digit decimal value (010-255) + [ENTER] 29 Intellizones Zone Definitions 7. 4 Feature Select Programming è Address 096, keys [1] to [10] Using the "Feature Select Programming Method", select which zones will be defined as Silent Zones. If an alarm occurs on a Silent Zone, the control panel will report the alarm (see Event Reporting in section 6) to the central station without triggering any bells and/or sirens. Note if zone 3 is defined as 24 hour (fire zone), the control panel will generate an audible alarm, overriding a silent zone definition. Silent Zones 7. 5 Feature Select Programming è Address 100 , keys [1] to [10] Using the "Feature Select Programming Method", select which zones will be defined as 24 hour Zones. Regardless of the system's armed status, an open "24hr" zone will always generate an alarm. If zone 3 is defined as "24 hour", it becomes a "Fire Zone". An open "Fire Zone" will generate the following: u The panel will send a fire loop trouble report (if programmed at address 500) to the Central. u A trouble indicator, key [11], and a fire zone indicator, key [3], will flash on the keypad. u The 728+'s fire alarm will generate an intermittent output signal and the 728EX+'s fire alarm will generate a pulsed output signal, regardless of the system's current arming status. [. . . ] This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ESPRIT 728 PLUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ESPRIT 728 PLUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.