User manual DOMETIC BRISK AIR HP INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC BRISK AIR HP. We hope that this DOMETIC BRISK AIR HP user guide will be useful to you.


DOMETIC BRISK AIR HP INSTALLATION: Download the complete user guide (728 Ko)

You may also download the following manuals related to this product:

   DOMETIC BRISK AIR HP PARTS LIST (207 ko)

Manual abstract: user guide DOMETIC BRISK AIR HPINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46, Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center Assistance Call: 800-544-4881 520 Series DUO-THERM HP 530 Series DUO-THERM HP HEAT PUMP 579 Series BRISk AIR 590 Series BRISk AIR 591 Series HEAT PUMP 595 Series QUICk COOL 600 Series PENgUIN 630 Series PENgUIN Roof Top Air Conditioners & Heat Pumps Used With Part No. 3109226. 005 & 3109407. 001 Comfort Control Center Electronic Control kit Ducted Installation Using 3109228. 001 (White) Comfort Control CenterTM OR 3109228. 019 (Black) Comfort Control CenterTM THIS UNIT IS DESIgNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY DOMETIC CORPORTION This manual must be read and understood before installation, adjustment, service, or maintenance is performed. Modification of this product can be extremely hazardous and could result in personal injury or property damage. Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. L'installation de cet appareil doit être effectuée par un réparateur qualifié. [. . . ] Make sure that at least 15" of supply wire extends into the roof opening. For multiple zone installation, this wiring is required in only one of the 14-1/4" x 14-1/4" (±1/8") openings. Choose the shortest, direct route from the 14-1/4" x 14-1/4" (±1/8") opening to the Comfort Control CenterTM (CCC) location selected, and route a 4-conductor flat control cable. Make sure at least 15" of wire extends into the opening and 6" extends from the wall at the Comfort Control CenterTM (CCC) location. If a remote temperature sensor is to be used, the connector end must be routed to the roof opening of the system which it will control. If an Energy Management System-EMS (load shed) is to be used with the control system, two wires must be routed to the roof opening of the zone to be managed. The signal required for this function is a normally open relay contact. When the EMS calls for the compressor to shut off, the relay contacts should close. Make sure that at least 15" of the EMS wires extend into the roof opening. If system is to control a gas furnace, route two 18 gauge wires from the furnace to roof opening of the air conditioner that will control it. If more than one furnace is to be used, route the second set of wires to the second air conditioner. In the event that other air conditioners are to be installed (additional zones) route an additional 4-conductor control cable between the other air conditioner (additional zones). 6. 10 Black Red green Yellow Pin 1 CCC Ducted Installation Instructions FIg. PLACINg THE AIR CONDITIONER ON THE ROOF This unit weighs approximately 100 pounds. To prevent back injury, use a mechanical hoist to place air conditioner on roof. C. Lift and place the unit over the prepared opening using the gasket on unit as a guide. The roof gasket on the bottom of the base pan goes toward the front of the RV. This may damage the neoprene gasket attached to the bottom and create a leaky installation. D. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/8") opening previously cut. Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. Plug the freeze control sensor cord into the mating connector on the Electronic Control kit. 9 520, 530, 579, 590, 591 & 595 FREEzE CONTROL 600 & 630 FREEzE CONTROL FIg. [. . . ] Note: Dip switches are in the "OFF" position when shipped from the factory. Note: The dip switches are visible through the opening in the ceiling template into the control box. 21 DO NOT USE A BALL POINT PEN To Move Dip Switch Use Flat Blade Screw-driver Wider Than Dip Switch Slot to Move Dip Switch FIg. 22 Mode Push-Button Fan Push-Button Up Push-Button Down Push-Button zone Push-Button ON/OFF Switch Not Correct Correct Important: Dip switch damage will occur if they are not set in proper manner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC BRISK AIR HP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC BRISK AIR HP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.