User manual DOMETIC AIR DISTRIBUTION BOX INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC AIR DISTRIBUTION BOX. We hope that this DOMETIC AIR DISTRIBUTION BOX user guide will be useful to you.


DOMETIC AIR DISTRIBUTION BOX INSTALLATION: Download the complete user guide (3327 Ko)

You may also download the following manuals related to this product:

   DOMETIC AIR DISTRIBUTION BOX PARTS LIST (318 ko)

Manual abstract: user guide DOMETIC AIR DISTRIBUTION BOXINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Date Purchased AIR DISTRIBUTION BOX KITS Patents Pending Product USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 4656 574-294-25 CANADA Dometic Distribution 46 Zatonski, Unit 3 Brantford, Ontario CANADA N3T 5L8 59-720-9578 For Service Center Assistance Call: 800-544-488 Type Mechanical Controls Mechanical Controls Electronics Pre-installed In Unit For Use With 520 Series/ 600 Series 520300/600 Series 6204, 6205, 6206, 6207, 6305 Electric Heat Opt Kit/Not Avail Not Available Pre- Installed In Unit (Except 6305) 3310700 3310741 3310742 Note: Installation requires a #2 phillips screwdriver with 9/32" maximum diameter x 1-1/4" minimum This manual must be read and understood before installation, adjustment, service, or maintenance is performed. Modification of this product can be extremely hazardous and could result in personal injury or property damage. Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. L'installation de cet appareil doit être effectuée par un réparateur qualifié. Toute modification de cet appareil peut être extrêmement dangereuse et entraîner des blessures ou dommages matériels. INSTALLATION & OPERATING INSTRUCTIONS REVISION: Form No. [. . . ] · Use a steel sleeve and a grommet or equivalent methods to protect the wire where it passes into the opening. Route a dedicated 2 VDC supply line (8-22 AWG) from the RV's converter or battery to the roof opening. · This supply line must be located in the front portion of the 4-/4" x 4-/4" (±/8") opening. · Make sure that at least 5" of supply wire extends into the roof opening. If a furnace is to be controlled by the system, the two furnace thermostat leads must be routed to the roof opening of the air conditioner that will control it. Make sure that at least 5" of the furnace thermostat wires extend into the roof opening. Route a 4-conductor control cable from the Digital Thermostat mounting position into the 4-/4" x 4-/4" (±/8") roof opening. Make sure that at least 5" of the wire extends into the roof opening and 6" extend from the wall at the mounting position of the Digital Thermostat. Dometic Digital Thermostat & Cable Installation Location · Locate the Digital Thermostat 54" above the floor. · Install the Digital Thermostat on a partition, not on an outside wall. · NEVER expose it to direct heat from lamps, sun or other heat producing items. · Avoid locations close to doors that lead outside, windows or adjoining outside walls. · Avoid locations close to supply registers and the air from them. · A 3/8" diameter hole will be needed to route the cable through the wall. · Control Cable Installation · A 4-conductor control cable (flat telephone type) must be routed from the roof opening to the Digital Thermostat. · Choose the shortest, most direct route from the 4-/4" x 4-/4" (±/8") opening to the Digital Thermostat location selected. Digital Thermostat Installation · Carefully remove the base plate from the Digital Thermostat. This may be accomplished by pushing a small screwdriver in the slot on the bottom edge of the front cover to release latch. · INSTALLATION INSTRUCTIONS · Insert the control cable through the hole in the base plate and mount the plate to the wall with two (2) screws provided. Install the control cable RJ--6C4P connector into the back of the Digital Thermostat and snap onto the base plate. 6. PLACING THE AIR CONDITIONER ON THE ROOF This unit weighs approximately 100 pounds. To prevent back injury, use a mechanical hoist to place air conditioner on roof. A. Remove wire tie holding center of rear aluminum bracket to plastic template. [. . . ] Note: Never run the air conditioner without return air filters in place. Dust may plug the unit evaporator coil and may substantially affect the performance of the unit. AIR BOX HOUSING: Clean air box housing and control panel with a soft cloth dampened with a mild detergent. FAN MOTOR: Factory lubricated and requires no service under normal use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC AIR DISTRIBUTION BOX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC AIR DISTRIBUTION BOX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.