User manual CITADEL XR1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITADEL XR1. We hope that this CITADEL XR1 user guide will be useful to you.


CITADEL XR1 : Download the complete user guide (542 Ko)

Manual abstract: user guide CITADEL XR1

Detailed instructions for use are in the User's Guide.

[. . . ] This is an armed system indication. 4188-693 issue 1_8/01 1 Downloaded from: http://www. guardianalarms. net Unset system indications Accenta/!mini For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine. Operating instructions Contents Unset system indications - - - - - - - - Set System indication - - - - - - - - - Access codes - - - - - - - - - - - - - How to operate Personal Attack - - - How to unset system in alarm - - - - - Programs 1, 2 and 3 - - - - - - - - - - How to set the system (on program 1) - Push to Set Switch - - - - - - - - - - - Keyswitch Set - - - - - - - - - - - - - Faults during setting - - - - - - - - - - How to unset the system (turn off) - - How to set program1, 2 or 3 - - - - - - How to Quick set - - - - - - - - - - - How to Omit zone(s) on setting system Fire Alarm - - - - - - - - - - - - - - How to set Chime Zones - - - - - - - Operator's Program mode - - - - - - - To exit operation at any time - - - - - - How to enter Operator's program mode How to view the events log - - - - - - How to create/omit User 2 code - - - - How to change current user code - - - How to carry out Alarm and Walk testsServicing organisation details - - - - - - Quick Reference - - - - - - - - - - - - 1 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 5 5 5 5 6 6 7 7 8 Citadel XR1 G3 Intruder system How to unset system in alarm Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. [. . . ] The system is unset and disarmed. Entry beep Day n n n n Acknowledge Day Push to Set Switch In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting How to set program 1, 2 or 3 procedure once the building has been vacated. As the switch is operated, the exit beep tone will The green Day indicator should be showing. stop and a chime tone will be produced to Enter your code Day acknowledge setting. Press Exit beep the Prog key and Keyswitch Set the exit tone will ZONE 1-3 Prog Exit beep stop. Press 1, 2 Your system may have been fitted with a remote or 3 for the keyswitch. This can be used as an alternative to 2 Or 3 1 required arming the system with a code and will set program, the Program 1. 10 seconds Exit beep insistent beeps sounder will Where a keyswitch is used it may be necessary beep to Day on occasions to allow it to catch up with the acknowledge the system. For example if the alarm was set with a code, to Unset with the keyswitch, it would have program number. The exit beep tone will start to be momentarily turned to Set then returned to and you should leave by the approved route. It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set. Faults during setting If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system. 4188-693 issue 1_8/01 3 How to set the system (on program 1) Operating instructions Citadel XR1 G3 Intruder system How to Quick set During the exit period (on entering User code) the system may be Set quickly by pressing Set. Set a Program Set 5 seconds insistent beeps Day How to set Chime Zones Example: To set zone 3 and 4 to chime, Press: Chime 3 Day 4 Reset If you omit zones and require Quick Set, you will need to press Set twice. Chime Timeout after 5 seconds if no selection is made Day Chime 0 Deselect all zones (Factory default - no chime) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show chime zone(s) Zone n Chime selected Zone n Chime deselected How to Omit zone(s) on setting system Press number button to select / deselect Zone Chime 1 2 3 4 5 6 7 8 During the exit period after entering User code and selecting a program press Day OMIT, the exit Set the system or tone will stop and Set a Program and while the zones that are system is setting: about to be armed will be displayed. Omit ZONE(S) TO BE ARMED Key in the zone Exit beep number(s) to be omitted which will Press the zone(s) n flash to confirm to be omitted selection. Zone ZONE(S) TO BE OMITTED indicators which show steady are Set still about to be 10 seconds Exit beep armed. [. . . ] As each operation is completed the system will automatically return to top level of program mode. How to view the events log The panel can hold up to 8 previous events which can be scrolled automatically or manually. The automatic scroll starts with the newest event ( number 8) to the oldest one ( number 1). Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog 0 1 2 3 Chime Reset Note: When programming the system should be in the Day mode, with the Day and Power indicators lit. Enter Operator's program mode Chime View the event log Tamper To exit operation at any time On pressing the Reset key you will quit the current level of operation. Reset Automatic event scroll Starting from event 1 to 8 To manually scroll View event 1 1 (oldest event) 2 3 Zone, PA and Tamper indicators will be lit to show zone in alarm. Day indicates status of panel at the time of alarm Quit the current function Leave Engineering menu Down one menu level View event 2 View event 3 View event 4 View event 5 View event 6 View event 7 How to enter Operator's program mode To enter the Operator's program mode the system should be in Day Prog mode with the Day and ZONE 1 - 8 Power indicator lit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITADEL XR1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITADEL XR1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.