User manual CISSELL LOWBOYMAN44

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL LOWBOYMAN44. We hope that this CISSELL LOWBOYMAN44 user guide will be useful to you.


CISSELL LOWBOYMAN44 : Download the complete user guide (418 Ko)

Manual abstract: user guide CISSELL LOWBOYMAN44

Detailed instructions for use are in the User's Guide.

[. . . ] BOX 32270 LOUISVILLE, KY 40232-2270 PHONE: (502) 587-1292 SALES FAX: (502) 585-3625 SERVICE/PARTS FAX: (502) 681-1275 MAN44 3/97 Page 1 F. Take support spring (6) and connect S hook to hose support clamp (7) pinch S hook closed. Insert support string (6) end into Low Boy (8) support spring plate and tighten square head set blot. [. . . ] Screw Rating Nameplate 1/2 x 3 Pipe Nipple 1/2 Pipe Tee Switch Cover Plate Double Pole Switch Amber Light 110V Amber Light 220V Box Welded Asm. Terminal Mounting Plate Terminal Block 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 LB59 . . . . . . . . . . . . . Label Heyco Bushing Cup Washer Green Ground Screw 1/2 Close Nipple Condenser Assy. 50/60 Cy. ) Not Illustrated Page 4 INSTALLATION SET UP: Set unit in position and fasten securely to board. IMPORTANT: Before making steam return connections to unit, make steam supply connections. Remove all drain plugs, open steam supply globe valve to steam-flush any borings, grindings or foreign matter that may be clinging within casting or pipes. Close globe valve; replace drain plugs and make steam return connections. Before attaching steam hose from steam-electric iron to solenoid valve, with steam pressure on unit operate thumb switch several times to remove loose particles of scale dirt, which may become embedded in valve seat. STEAM SUPPLY: Steam supply connection must fall towards machine (without water pockets). Make connection with 12 or more riser out of steam supply line with union and globe valve. (NOTE: If machine is on the end of a line of equipment, then extend steam header line at least four feet beyond machine. If gravity return omit trap. ) STEAM RETURN: If steam is returned to atmosphere or sewer, make steam return connection with union, globe valve, check valve and trap with drain. If steam is gravity returned to boiler, omit trap, but install trap as close to floor and as near machine as possible. Inspect traps carefully for inlet and outlet marks and install according to factory instruction. [. . . ] Wait until iron becomes hot then push electric thumb switch of iron to allow steam to flow from soleplate of iron. Screw valve knob in for less steam, out for more. MECHANICAL MAINTENANCE To replace coil in solenoid valve, remove bolt, cover, leaf spring, insulating washer and coil. To replace renewable valve seat or plunger, unscrew large hex nut from lower cast body. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL LOWBOYMAN44




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL LOWBOYMAN44 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.