User manual CANDY PG750

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY PG750. We hope that this CANDY PG750 user guide will be useful to you.


CANDY PG750 : Download the complete user guide (639 Ko)

Manual abstract: user guide CANDY PG750

Detailed instructions for use are in the User's Guide.

[. . . ] The distance between the hob and any other unit or appliance above it (e. g. When there is an accessible space between the built-in hob and the cavity below, a dividing wall made of insulating material should be inserted (wood or a similar material). 3) Important - The diagram below shows how the sealant should be applied. Plan 60 Plan 75 The Hob unit is fitted by attaching the Fixing Clamps supplied, using the holes at the base of the unit. Fig. 2 40 GB IE If a hob of 60 cm is fitted above an oven which is not equipped with fan cooling system it is recommended that openings are created within the built in furniture to ensure correct air circulation. [. . . ] All work must be carried out with the electricity supply disconnected. The rating plate on the hob shows the type of gas with which it is designed to be used. It is possible to use other types of gas after carrying out some simple modifications. connection to the mains gas supply or gas cylinder should be carried out according to the relevant national standards, after having checked that it is regulated for the type of gas with which it will be supplied. If it is not correctly regulated follow the instructions in the paragraph entitlet Adaption for different types of gas. For liquid gas (cylinder gas) use pressure regulators which comply with the relevant national standards. N. B. : for safe operation, economic use of energy and to ensure greater durability of the appliance, make sure that the supply pressure conforms with the values shown in the table on page 45. Use only pipes, washers and sealing washers which comply with the relevant national standards. When connecting the hob to the gas supply via use of flexible hoses please ensure that the maximum distance covered by the hose does not exceed 2 metres. N. B. : carry out a final check for leaks on the pipework using a soapy solution. Also, make sure that the flexible pipe cannot come into contact with a moving part of the cabinet (eg, a drawer) and that it is not situated where it could be damaged. IE GB 43 To prevent any potential damage to the hob please carry out the installation following this sequence: GB IE 1/2 GAS CONICAL A) As illustrated, assemble parts in sequence: A) fixed pipe B) washer C) Elbow fitting with tapered thred connection 2) Tighten the joints with the Spanners, remembering to twist the pipes into position. 3) Attach fitting C to mains gas supply using rigid copper pipe or flexible steel pipe. Please note Some models are equipped with both conical and cylindrical connectors for gas supply. Please select the type which is correct for the supply concerned. Fig. 5 A Cylindrical (but connector) B Tapered thread conical ADAPTING THE HOB TO DIFFERENT TYPES OF GAS To adapt the Hob for use with different types of gas, carry out the following instructions: -- remove the grids and burners -- insert the hexagonal spanner (supplied) into the burner support (Fig. 6) -- unscrew the injector and replace it with one suitable for the gas to be used (see Table of gas consumption) -- carry out regulation of the burner. Hexagonal spanner Fig. 6 44 GB IE Table of gas consumption G20/G25 G30 G31 G20 20mbar G30 29mbar G31 37mbar 1W = 0, 860 kcal/h G25 25mbar G20 X dimension according to Gas type G30 G25 G31 Working burner large medium maxi double ring fish gas jet gas jet 1/100 mm 1/100 mm 120 80 93 61 2x94 2x65 2x94 2x65 2x94 2x65 STD. Dim kW 2, 65 1, 5 3, 3 3, 3 3, 3 l/h G20 252 143 314 314 314 g/h G30 193 109 238 238 238 g/h G31 189 107 236 236 236 Qn kW 2, 5 1, 45 3, 1 3, 1 3, 1 l/h G25 277 161 343 343 343 min. Dim kW 0, 65 0, 38 0, 9 0, 9 0, 9 reg. air 5 mm 7 mm 15 mm 15 mm 15 mm SETTING OF THE GAS BURNERS When the jets have been changed it is necessary to set the correct air gap by keeping to the setting "X" as shown in the table " gas consumption" fig 7. Warning the value of ` X ` setting varies in relation to the size of gas burner and type of gas chosen. A good flame must be of medium length (fig. 8B), excessive air will cause the flame to be short and with sharp colour (fig. 8C): in this case it is necessary to extend out the tube for the air setting from the burner body, if there is insufficient air the flame will appear weak and long (fig. 8A): in this case push the tube of the air setting back into the burner body. 7). For dimensions X see table of gas consumption BURNER FIXING SCREW SMALL MEDIUM LARGE BURNER CAP AIR REGULATION SCREW DOUBLE RING MAXI FISH Fig. [. . . ] If the fault cannot be identified: switch off the appliance -- do not tamper with it -- call the Aftercare Service Centre. Chromed grids and burners Chromed grids and burners have the tendency to dark with the use. This is a normal and inevitable phenomenon, but it doesn't jeopardize absolutely the functionality of the hob. In anycase from our after sales service centre the spare parts are available. COVER The cover is available as optional accessory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY PG750




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY PG750 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.