User manual CANDY CE 520 T

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY CE 520 T. We hope that this CANDY CE 520 T user guide will be useful to you.


CANDY CE 520 T : Download the complete user guide (1530 Ko)

Manual abstract: user guide CANDY CE 520 T

Detailed instructions for use are in the User's Guide.

[. . . ] Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and are supplied by other than electrical energy, as the cooker hood removes the air from the environment which a burner or fireplace need for combustion. The negative pressure in the environment must not exceed 4Pa (4x10-5 bar). Before connecting the model to the electricity network: - control the data plate (positioned inside the appliance) to ascertain that the voltage and power correspond to the network and the socket is suitable. - If the power supply cable is damaged, it must be replaced with another cable or a special assembly, which may be obtained direct from the manufacturer or from the Technical Assistance Centre. [. . . ] - This device must be connected to the supply network through either a plug fused 3A or hardwired to a 2 fase spur protected by 3A fuse. A) Do not check the status of the filters while the cooker hood is operating B) Do not touch bulbs or adjacent areas, during or straight after prolonged use of the lighting installation. C) Flambè cooking is prohibited underneath the cooker hood D) Avoid free flame, as it is damaging for the filters and a fire hazard E) Constantly check food frying to avoid that the overheated oil may become a fire hazard F) Disconnec t the elec trical plug prior to any maintenance. G) This appliance is not intended for use by young children or infirm persons without supervision H) Young children should be supervised to ensure they do not play with the appliance I) There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas or other fuels L) There is a risk of fire if cleaning is not carried out in accordance with the instructions Assembly and electrical connections must be carried out by specialised personnel. Electric Connection The appliance has been manufactured as a class II, therefore no earth cable is necessary. The connection to the mains is carried out as follows: BROWN = L line BLUE = N neutral If not provided, connect a plug for the electrical load indicated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. An omnipolar switch with a minimum opening of 3mm between contacts, in line with the electrical load and local standards, must be placed between the appliance and the network in the case of direct connection to the electrical network. The minimum distance between the support surfaces of the cooking pots on the cooker top and the lowest part of the cooker hood must be at least 65 cm. - If the hood is a filter model, the lever D must be positioned as indicated in figure 4. Extractor version The appliance expels the fumes through an outside wall or a duct. It is necessary to buy a telescopic pipe in accordance with the standards in use (inflammable) and connect it to flange D (Fig 1A). The flange D is supplied with the product and should be fixed above the air outlet hole of the hood as indicated in figure 3. Filtering version To transform an extractor hood version into a filter hood version, contact your appliance dealer and ask for active charcoal filters. The filters should be fitted to the extraction assembly inside the hood, by centring them and rotating them 90 degrees, until they click into place (fig. To carry out this procedure, remove the grille D as demonstrated in figure 6. Close the air outlet opening with the plug B, as indicated in figure 4. The anti-grease filters capture the grease particles suspended in the air, and are therefore subject to clogging according to the frequency of the use of the appliance. [. . . ] Close the air outlet opening with the plug B, as indicated in figure 4. The anti-grease filters capture the grease particles suspended in the air, and are therefore subject to clogging according to the frequency of the use of the appliance. In order to prevent fire hazard, it is recommendable to clean the filter at a maximum of 2 months by carrying out the following instructions: - Remove the filters from the cooker hood and wash them in a solution of water and neutral liquid detergent, leaving to soak. The filters are not washable nor re-useable and must be replaced at maximum every four months. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY CE 520 T




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY CE 520 T will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.