User manual AVIOM 6416O

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AVIOM 6416O. We hope that this AVIOM 6416O user guide will be useful to you.


AVIOM 6416O : Download the complete user guide (8030 Ko)

You may also download the following manuals related to this product:

   AVIOM 6416O ADDENDUM (274 ko)

Manual abstract: user guide AVIOM 6416O

Detailed instructions for use are in the User's Guide.

[. . . ] 1. 00 © 2006 Aviom, Inc. Certifications ETL/cETL Listed EMC: Conforms to: Certified to: RoHS Status: EN 55103-1, EN 55103-2, SAA AS/NZS 1053 IEC 60065, EN 60065, UL 60065 CAN/CSA E60065, KETI Pb-free Notice of Rights All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means--electronic, mechanical, photocopy, recording, or otherwise--without written permission of Aviom, Inc. Trademarks Aviom and the Aviom logo are trademarks of Aviom, Inc. Printed in USA ii WARNING! NO USER SERVICEABLE PARTS INSIDE ! REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY · To reduce the risk of fire or electrical shock, do not expose this product to rain or other types of moisture. · Operating Temperature: 10°C to 50°C (50°F to 122°F) Risk of electric shock! [. . . ] The VDC interface includes the numeric VDC Slot display, the inc/dec buttons used for VDC Slot selection, the Assign Port list of VDC data types, and a selection button for choosing a VDC data type for the currently selected VDC Slot. VDC Slot display In Use LED inc/dec button VDC port assignments VDC port selection The VDC section of the user interface is used to assign VDC ports and data types. VDC Slot Display The two-digit VDC Slot display shows the currently selected VDC Slot (1 through 14). The In Use LED within the display indicates that a selected VDC Slot has an active input somewhere in the network. If only an output is assigned to a particular VDC, its In Use LED will not be lit. vdc coNfigurAtioN When a rear-panel VDC port has been assigned to a VDC Slot, its In Use LED will be on. Selecting a VDC Slot is done with the inc/dec buttons below the display. Pressing the inc/dec buttons will cause the display to scroll, and will wrap at the end of the numeric list. As the VDC Slots are displayed, any VDC Slot with an active input will light the In Use LED. If the In Use LED is not lit for a selected VDC Slot, no input is assigned to that VDC Slot and all of the VDC type LEDs in the Assign Port list will be unlit when the VDC out has been assigned locally. The available VDC data types for the 6416o are: · RS-232 · MIDI In · MIDI Out · GPIO In · GPIO Out VDC In Use LED The VDC In Use LED serves to indicate that a Virtual Data Cable Slot has a current active input assignment. Output assignments for MIDI Out or GPIO Out will not light the In Use LED. The In Use LED will light whenever a valid assignment (GPIO In, MIDI In, or RS-232) has been made anywhere in the network. The VDC Slot can only be used for the assigned data type until it has been deactivated at the point in the network where the input source has been assigned. 4 vdc coNfigurAtioN Assigning a VDC Slot The act of assigning a VDC Slot maps one of the rear-panel hardware VDC I/O ports to a Virtual Data Cable. First an available VDC Slot must be selected, and second, one of the VDC data types from the Assign Port list must be assigned to that VDC Slot. To select a VDC Slot to activate, scroll through the list to a numbered location that does not have the In Use LED lit. To assign a data type, use the selector button below the Assign Port list to select the desired VDC data type, for example MIDI In. The LED next to the selected type will light; the Enter/Cancel LED will also start to flash. Press EntEr to enable the VDC Slot; press CanCEl to exit without assigning a VDC port. To output VDC data from the network to a rear-panel VDC port, choose a VDC Slot with an In Use LED on with the appropriate data type (for example, MIDI) for the application. Once selected and configured, the rear-panel I/O connection for the selected VDC can be used to transfer control signals. Deactivate an Active VDC Slot To release an active input assigned to a VDC Slot, use the inc/dec button to scroll to the active VDC Slot. (Its In Use LED should be on. ) Press the selector button below the Assign Port LEDs until no VDC data type LED is lit. Press EntEr to deactivate the VDC Slot assignment and make that VDC Slot available to other modules in the network. Note: Only VDC inputs need to be deactivated to free Virtual Data Cable resources. [. . . ] By setting the FOH input module7to 8 9 its A-Net data to Port send 10 B A A and B, the A-Net data flows in two directions. Digital audio arriving B A at the front-of-house location from the stage is replaced by the input Merger module at FOH. Merger 1 2 the 5 6 7 8 9 10 To send the stage audio to 3 4 recording system instead, set the input module at front-of-house to send its data out Port A only. By doing this, the audio from the stage flows through all the modules to the recording system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AVIOM 6416O




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AVIOM 6416O will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.