User manual AIRWELL SPH BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AIRWELL SPH. We hope that this AIRWELL SPH user guide will be useful to you.


AIRWELL SPH BROCHURE: Download the complete user guide (818 Ko)

Manual abstract: user guide AIRWELL SPHBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] It will then automatically switch to a lower air flow to quietly maintain the selected temperature. 2 AUTO COOLING/HEATING OPERATION Select the AUTO mode by pressing MODE button (2). Switch to the desired FAN SPEED or to AUTO FAN by pressing button (4). The air flap will automatically move to either horizontal air delivery for cooling or to vertical air delivery for heating. At start, the air conditioner will select its mode of operation according to the room temperature and the temperature setting. [. . . ] Fan might terminate operation from time to time to prevent from over cooling. By selecting the mode, the air flap will move automatically to optimal horizontal air delivery position. SELECTING THE TEMPERATURE Press TEMP button (5) to change the temperature setting in the LCD operation display(13). The temperature setting is shown in degrees centigrade. I FEEL/ROOM TEMP FUNCTION OPERATION Press button (3) to activate the I FEEL function. Make sure that the remote control unit is aimed at the air conditioner, with the I FEEL sensor (14) in front. Prevent the I FEEL sensor from being affected by heat sources such as lamps, heaters, direct sun, etc. These may cause the sensor to transmit the Wrong temperature data, thereby disturbing the performance of the I FEEL function. By pressing on ROOM temperature, the measured room temperature and the room temperature sign will be displayed. To cancel the ROOM Temperature display press on one of the following: Press again on ROOM temperature button (3). Change of MODE button (2) Note: Room temperature range is between 6 and 36 in 1 increments. 2. The timer mode will display always the last ON and OFF settings on the LCD display 5 SETTING THE ON AND OFF TIMERS Undertake the following steps after selecting a timer-T1, T2 or WKT1, WKT2, to set a timer for the start and stop time of operation. conditioner ON at 10:30. and OFF at 18:30. Set the hours and minutes. Press the SET button The ON icon & ON time digits will blink 1. Set the ON time at 10:30 2. Press the (HOUR+) up button to advance the time, and press the (HOUR-) down button retract. 1. The ON time is activated at 10:30(the time ON icon will light) 2. Timer OFF icon & OFF time digits will blink. 1. Set the OFF time at 18:30 2. Press the (HOUR+) up button to advance the time, and press the (HOUR-) down button retract. OFF time is activated at 18:30 (the timer OFF icon will light) TO CHANGE THE TIME SETTING EXAMPLE: To change the ON time setting from 10:30 to 9:20 (while preserving the OFF time 1 setting) Press the TIMER Press the SET button. Change the setting Press the SET time to 9:20 by button to save the pressing on new setting. Press the SET button to confirm the previous timer OFF setting 2 3 4 5 Note that the corresponding formerly set timer digits will display without blinking. ON icon & ON time digits blink ON icon & ON time digits blink ON icon & ON time digits light while OFF icon & OFF time digits blink. ON & OFF icons and time digits of the consequent timer light 6 TO CANCEL THE TIMER SETTING FOR A PARTICULAR TIMER To cancel the ON time while keeping the OFF time setting. Press SET button Press TIMER button to select a timer. 1 The selected timer icon ON icon & ON time digits blink. blinks & the corre spending previous timer ON, OFF settings light. ON time is cleared, OFF icon & OFF time digits blink. Confirm the new setting. TO CANCEL THE ON & OFF TIME SETTIINGS Press TIMER button to select a timer. Press CLEAR button. 1 The selected timer icon blinks & the corre spending previous time ON, OFF settings light. All settings of the selected timer are cleared. NOTES: 1. The default settings for the timers are 7:00 and 18:00, for ON and OFF respectively. 2. The timer mode will always display the last ON and OFF settings on the LCD display. 3. Pressing CLEAR button (12) for 5 seconds will cancel all timer settings and clear timer display. 7 AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT Press button (7) to activate the supply air flap to auto swing; Press button (8) to activate the Horizontal Air Flow to auto swing. [. . . ] 3. Pressing CLEAR button (12) for 5 seconds will cancel all timer settings and clear timer display. 7 AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT Press button (7) to activate the supply air flap to auto swing; Press button (8) to activate the Horizontal Air Flow to auto swing. Each time the button is pressed, the fan speed is changed in sequence: To change the AIR FLOW blowing direction vertically, press the button. Each time the button is pressed, the mode of the HORIZONTAL VANE is changed in sequence: Auto Swing Auto To change the AIR FLOW blowing direction horizontally, press the button. Each time the button is pressed, the mode of the VERTICAL VANE is changed in sequence: Auto Swing Auto 1) Strong fan will only operation cooling & heating mode 2) Strong fan option is selectable via switch TURNING OFF THE AIR CONDITIONER Press Start /Stop button(1) to turn off the air conditioner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AIRWELL SPH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AIRWELL SPH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.